Solution Suggestion

CP Error

The Control Pilot (CP) 
connection is not reliable

Check that your Control Pilot(CP) signal 
pin isn’t shor ted. Contac t the Ev One 
provider if this problem persists.

Low voltage

System voltage is lower than 
workable range

Consult your elec trician to ensure 
appropriate voltage on the circuit 
breaker that ser vices the Ev One.

Over voltage

System voltage is higher than 
workable range

Consult your elec trician to ensure appro -
priate voltage on the circuit breaker that 
ser vices the Ev One.

Ungrounded

The ear th ground connection is 
not reliable

Check if your circuit ground connec tion 
is established. If uncer tain, consult your
elec trician to ensure proper grounding 
at your circuit breaker or power 
distribution box and that appropriate 
connec tions are made to the Ev One.

Over Current

The output current is 
dangerously increasing

Reduce the vehicle’s charge current 
setting. If the problem persists, contac t 
Ev One provider.

Shor t Current

An excessive amount of current 
flowing into the circuit in a 
shor t time

Possible causes include shor t circuits, 
excessive load, or a ground fault( see 
Ungrounded error). Check wiring or 
wiring connec tions, or contac t Ev One 
provider.

Leakage protec tion

A dangerous voltage is 
detected

Consult your elec trician

Over temperature

The temperature is higher than 
workable range

Make sure the connec tor is fully inser ted 
into the charge inlet in the vehicle, and 
is not covered by anything, and no heat 
source is nearby. If the problem persists 
in normal ambient temperatures(under 
50°C or 122°F), contac t provider

Emergenc y stop

The charger doesn’t work 
immediately

Stop using the Ev One and contac t the
Ev One provider

7