NOTE: Maintain a large radius on the bends of the thermocouple. Be careful NOT TO BREAK
the thermocouple at the burner joint.
4.
Verify the connections of the Thermal Cut-off that is in line with the red wire on the Shutdown
Relay Assembly.
Verify both the mechanical integrity of the connections and the electrical
continuity of the Thermal Fuse within.
Figure 5 – Installation of Spark Igniter and Fuel Line
3.4
INSTALLING THE SPARK IGNITER ELECTRODE
To install the Spark Igniter Electrode:
1.
Slide the Spark Igniter Electrode through the fitting on the bottom of the burner until it touches
inside, then pull back by approximately 1/8 inch (3 mm). This should leave 2.63 to 2.75 inches (67
to 70 mm) extruding beyond the fitting, refer to
2.
Gently tighten the nut on the fitting to maintain the position of the electrode.
3.
Connect the terminal lug of the high-voltage cable to the end of the Spark Igniter Rod.
3.5
CONNECTING THE FUEL SUPPLY
WARNING!
Use only the type of fuel indicated on the data plate
. See Section 2.2.
The maximum inlet pressure to the TEG must never exceed 25 psi (172 kPa).
Before connecting the fuel supply to the TEG, review Section 3.1.3 and ensure that all necessary
precautions have been made based on the fuel supply used and the environmental conditions.