Maintenance
1)
Inspect the electrical cord and wiring for damage or discoloration before use. NEVER use a air scrubber that
has a damaged cord to avoid risk of electrical shock or fire.
2)
Inspect for loose fasteners before each use.
3)
Clean safety screens of the unit before each use.
4)
Listen for abnormal sounds and shut unit off immediately upon hearing unusual noises.
5)
Keep unit clean and free of blockages or obstructions.
6)
Use compressed air or a vacuum to remove lint and other debris from the motor, inlet, or fan blade.
7)
Do not use a pressure washer, water hose, or other water source to clean the unit. Ensure that the unit is
completely dry before each use.
8)
The air scrubber has sealed bearings and cannot be lubricated. No oiling is necessary.
For information about authorized repair and maintenance contact Global Industrial.
Filters
The air scrubber equip the 3 stage filters including 1 pre-pad filter, 1 pre filter, 1 optional carbon filter, 1 hepa filter.
1)
The pre pad filter and Prefilter is used for Captures the largest particles to help extend the life of hepa Filter.
2)
The hepa filter is used to against oily aerosol particles down to 0.3 microns
3)
The carbon filter is used to Captures a wide variety of volatile organic compounds (VOCs).
Change Filters
Pre-pad filter and Prefilter is recommend to change for every job like painting or depends on the appearance.
Hepa Filter need to be changed within 3 month or when the hepa change light is on.
Carbon Filter need to be changed monthly.
The user need to change all filters if there is risk of the cross-infection application, for example water
damage restoration, fire remold.
PLS WEAR MASKS WHEN CHANGE FILTERS.
Handle Assembly
The air scrubber has the metal handle for easy transportation.
Use the 4 screw to fix the handle on the housing.