background image

Global-Tek (Singapore) Pte Ltd 

 

                                                                              Page 1 

 

 

Double-Tank Conveyor Type 

Dish Washing Machine

 

 

Model - GT-CR2

 

 

Instruction & Installation Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

             

 

 

 

Содержание GT-CR 2

Страница 1: ...Global Tek Singapore Pte Ltd Page 1 Double Tank Conveyor Type Dish Washing Machine Model GT CR2 Instruction Installation Manual...

Страница 2: ...ndard Equipment 3 6 INSTALLATION 7 Unpacking 7 Assembly 7 Plumbing Connections 7 Drain Connections 7 Fill Connection 8 ELECTRICAL CONNECTIONS 9 10 OPERATION 11 Preparation 11 Operating The Machine 11...

Страница 3: ...tainless steel adjustable feet Front inspection doors provide ready access to the interior of the wash chambers This machine have 4 x 9 kW booster heater and is available with either steam or electric...

Страница 4: ...t stainless steel with stainless steel impeller Motor is available in the following voltages Volts Hz Phase 380 50 3 The conveyor motor is a 0 24 Kw gear motor with the same voltage as the wash pump m...

Страница 5: ...Only turn the breaker on after all tanks are filled otherwise the booster tank its heating elements will be damaged Rinse Booster Booster heater is equipped with 4 x 9 Kw heating elements Wash Auto t...

Страница 6: ...side of the control box Designed to save electrical power it is adjusted to shut off pump and drive motors and optional exhaust vent fan control after the last rack exits the dishwasher To restart sli...

Страница 7: ...st the height and level by turning the adjustable feet NOTE The dishwasher must be positioned and leveled before making plumbing connections ASSEMBLY Dish tables should be fitted into the dishwasher U...

Страница 8: ...ould not exceed 16kg cm2 otherwise the pressure regulator valve will be damaged This regulator is preset at the factory and no adjustment should be required ELECTRICAL CONNECTIONS Power connection Pow...

Страница 9: ...to the machine and interchange any two power supply leads at the control box terminal block Or machine with a circuit breaker reverse any two leads at the incoming power supply block in the circuit br...

Страница 10: ...ions Operating The Machine After machine has filled start pumps by pushing MOTOR switch to ON Stack dishes in the racks Do not stack dishes one on top of each other as water must have free access to b...

Страница 11: ...7 Clean dish tables into the dishwasher 8 Remove all strainer pans and strainer basket s Empty contents into garbage can or disposer and thoroughly clean pans and basket s 9 Remove and clean pump inta...

Страница 12: ...ay have more than one electrical power supply All supplies MUST be disconnected WARNING Disconnect Hi Limit protector circuit when repairing booster After service completed connect Hi Limit protector...

Страница 13: ...uction preventing proper drain closing 2 Drain valve allowing wash water to drain 3 Missing end plug from wash arm 4 Wash arm nozzle obstruction 5 Water leaking past manifold o ring 6 Loss of water pr...

Страница 14: ...e arms should be positioned so that the spray pattern is slightly toward the center of the dishwasher NOTE All machines may have alignment studs on the rinse arms that correspond to studs on the rinse...

Страница 15: ...ment 5 Problem with solenoid valve No Booster Heat or low water temperature 1 Check the solid state thermostat and probe 2 Check Hi Limit protector 3 Circuit breaker to heat system tripped 4 Is contac...

Страница 16: ...Global Tek Singapore Pte Ltd Page 16...

Страница 17: ...Global Tek Singapore Pte Ltd Page 17...

Страница 18: ...Global Tek Singapore Pte Ltd Page 18...

Отзывы: