DRAIN CONNECTION
Connect the drain through a trap to the sewer pipe.
FILL CONNECTION
Use pipe for the connecting line. The flowing pressure is preset 1.4kg/cm
2
. Water
flows into booster and is heated, then into wash tank. After the tank is filled, the
float-controlled high-water switch closes the solenoid valve. If during the operation
water level in wash tank is lower then the required water level, fill solenoid valve
will be opened to top-up the tank.
WARNING:
Do not operate the machine when flowing pressure is under 1.0 kg/cm
2
.
Low pressure may result in inadequate rinsing. The water fill connection must be
65
℃
maximum and flow pressure should not exceed 16kg/cm
2
, otherwise, the
pressure regulator valve will be damaged. This regulator is preset at the factory and
no adjustment should be required.
ELECTRICAL CONNECTIONS
Power connection
Power connection is housed in the control box.
NOTE:
Three power lines must connect to L1/L2/L3 of the junction line, and
neutral line connects to neutral line terminal block (neutral line is not required for
this machine). Earth line must be connected to the terminal block provided.
WARNING:
PRIOR TO CONNECTION, VERIFY THAT THE ELECTRICAL
SERVECE AGREES WITH THE SPECIFICATIONS OF THE MACHINE, WHICH
IS REFER TO THE OPERATION AND SERVICES MANUAL, POWER LINE
MUST COMPLY WITH THE CURRENT ON THE MACHINE DATA.
WARNING:
ELECTRICAL AND EARTH CONNECTION MUST COMPLY
WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL
CODE ANSI/NFPA 70 (LATEST EDITION) AND/OR OTHER LOCAL
ELECTRICAL CODES.