Front Panel Description
1. Display: Displays the measured values, selected function mode, and annunciators.
2. Power Button: Turns the meter on or off.
3. 10 A: The positive input terminal for up to 10 A current measurement.
4. mAhFE, TEMP : The positive input terminal for up to 400 mA, as well as for capacitive
and temperature measurements.
5. COM: The negative (ground) input terminal for all measurement modes. Connection is
made to it using the black test lead.
6. VΩHz : The positive input terminal for voltage, ohms, frequency and diode
measurements. Connection is made using the red test lead.
7. Function/Range Rotary Switch: Selects the function and desired range.
8. Backlight: Press to activate LCD backlight.
9. HOLD: Displays the current value on the display even if the leads are removed from device
under test. Pressing the button again returns to current reading measurement mode.
10. AC Voltage Sensor: Sensor for non-contact AC voltage detection.
11. AC Voltage Indicator: Indicator LED for AC voltage ≥110 Vrms.