background image

Advanced Setting

Power off state, long press

for 3-5 seconds to do advanced setting. Short press “ ” to switch and

confirm. Press “ ” and “ ” to adjust options.

After finish setting , stand for about 5 seconds ,it will save setting then exit .

Setting IP code

Power off state, long press

for 3-5 seconds to do advanced setting. Short press “ ” to switch and

confirm. Press “ ” and “ ” to adjust options.

After finish setting , standing for 5 seconds ,it will save setting then exit .

!

Considering battery usage, RF data updates every 20 minutes. If shorten interval, pls use USB

power and remove batteries. Follow B05, B06 operation.

NO

Setting Options

Data Setting Function

Factory

Default

B1

IP code low setting

00-FF

00

B2

IP code high setting

01-FF

01

B3

IP matching code

Display”55” means IP match successfully.

(When receiver is power-on, press

thermostat

successively)

00

B4

Sensor state

N1:single built-in sensor

N3

both built-in sensor and external sensor.

(when receiver with external sensor, this

option is automatically recognized and

cannot be changed)

N1

B05

Minute interval of RF

transmission

1: 1-30 minutes

2:0 B06

20 min.

B06

Second interval of RF

transmission

3-30 seconds

30 s

Receiver Indicator Light

Power-on light : green light

Load light/fault light : red light

A

When no fault: normally on when load output, light off when no load output

B

When fault: blinking

1. IP fault (IP:FFFF) : Light blinks 2 times every 2s

2. No wifi signal within 1h: Light blinks 3 times every 2s

3. External sensor fault: Light blinks 4 times every 2s

Sensor fault : Display “E1” or “E2” . Thermostat stop heating until the fault is eliminated.

RF matching light: orange light

(B3 IP matching code) When receiver is power-on, orange light is normally on within 10s. And

light off when finish matching. When receiver is power-off, orange light is blinking within 10s.

Wifi matching light: blue light

When power on state, long press receiver button“push” to match wifi. Normally on is EZ mode.

Blinking is AP mode. Successive blinking is matching.

Wiring Diagram

RISK OF ELECTRICAL SHOCK

Please arrange professional technician to install the product according to drawings and instructions.
Disconnect power supply before making any connection. Contact with components carrying
hazardous voltage can cause electrical shock.

NO

Description

Range

Default

A1

Temperature Calibration

-9-+9

0.5

A2

Switching Differential of

Built in Sensor

0.5-2.5

1

A3

Switching Differential

of External Sensor

1-9

2

A4

Children Lock

0:half lock

1:full lock

0

A5

Max temp of External

Sensor

1. 35

-70

2. When setting temp is lower than 35

, screen

displays

--

,

cancel highest temp protection

--

A6

Min temp of External

sensor

(anti-freeze protection)

1. 1-10

2. When setting temp is higher than 10

, screen

display

--

,

cancel anti freeze protection

5

A7

Max Temp Setting

1-10

5

A8

Min Temp Setting

20-70

35

A9

Descaling function

0:Close descaling function

1:Open descaling function

Function works for 3

minutes every no-operating 100 hours

0

AA

Power off Memory

0:Stay last state

1: Electricity turn off

2: Electricity turn on

0

AB

Weekly Programmable

Function

P1: 5+2 days

P2: 6+1 days

P3: 7 days

P1

AC

Factory defaults

Display A o, long press

until show the whole

screen

Отзывы: