第 5 页 共 17 页
types of batteries in series or parallel. This operation may cause
personal injury or property damage; it is forbidden to connect the
entire power system containing the lithium-ion battery management
system with other power systems in series or parallel Operation, this
operation may cause personal injury or property damage; in any case,
when testing or using the battery, the terminal voltage of the single
battery must be tested in real time to avoid overcharging or over
discharging the battery.
When the company stores for a long time, please charge the battery
with SOC to 80% and store it, and charge the battery once a month
(SOC to 80%).
II. Battery Pack Specification
2.1 Battery Pack Specification
No.
Function
Technical Specification
EV-CC48-450-I
EV-CC48-450-
II
EV-CC38-600-
I
Remark
1
Nominal
Voltage
51.2V
51.2V
38.4V
2
Voltage Range
40V-58.4V
40V-58.4V
30-43.8
Unit
Voltage
2.5v-3.65v
3
Battery Style
LiFePO4
Unit
Voltage
3.2v
4
Nominal
Capacity
450Ah
450Ah
600Ah
25
℃
,
0.3C
5
Instruction
System
16 Parallel
16 Parallel
12 Parallel
6
Max. Capacity
22kwh
22kwh
22kwh