Global Industrial 713166 Скачать руководство пользователя страница 5

   

 

After use or when the tank is full, press the switch button off to stop the machine, and pull the power cord plug 

from the outlet. Discharge the suction hose from suction hole, if it is necessary, also discharge the squeegee. 

Move the machine to an appropriate draining location and empty dirty water using the drain hose (tilt tank if 

needed). Clean thoroughly after each use. 

 

Maintenance 

Warning: Disconnect the power before any maintenance 

 

Periodically

1. 

Lift the motor head and check whether the filter absorbed water from excess foam. If the filter contains 

water, remove and check to see if the motor head area contains water as well. If this occurs, leave unit 

open until motor head is completely dry, at which point it is acceptable to reuse. If needed, allow motor 

head to sit upright in a ventilated area for 24 hours to dry.   

2. 

Check condition of HEPA filter and replace if needed. For replacement HEPA filters (model 713169) 

contact Global Industrial Customer Service at 1-800-645-2986 or visit www.globalindustrial.com. 

3. 

Clean tank and all accessories thoroughly with a wet cloth. 

4. 

Clean the float valve, make sure it can travel up and down freely and is not restricted. 

5. 

Clean motor head with damp cloth, DO NOT allow water to touch the motor directly. 

6. 

Remove the filter dust bag, empty and reattach. 

 

Troubleshooting 

 

PROBLEM 

ANALYSIST 

POSSIBLE SOLUTION 

Not Working 

Properly 

 

Not connected to power 

 

No power in the outlet 

 

Cable damaged 

 

Connect to power outlet 

 

Check the plug outlet fuse 

 

Replace the cable 

No Suction 

 

Floor nozzle, tube, hose or suction hole blocked 

 

Motor does not start 

 

The tank is full, but the float valve is not working 

 

Filter blocked 

 

Remove blockage 

 

Press on switch 

 

Empty tank 

 

Remove blockage 

Week Suction 

 

Filter severely dirty 

 

Floor nozzle, tube, hose or suction hole blocked 

 

Clean filter 

 

Remove blockage 

 

Transportation & Storage 

 

The machine must be operated, transported and stored upright. 

 

When transporting, remove all accessories and make sure all vacuum parts are secure. 

 

Before storing, empty and clean the tank thoroughly, wipe down all accessories and clean filters. 

 

Place machine in a dry and dustless area with no threat of freezing temperatures. 

 

 