Heavy Duty LED Digital Crane Scale W/Remote

BATTERY CHARGING INSTRUCTIONS

a. Then 

  indicator will be on if there is low power. The battery needs to be charged now. The scale, however, can 

continue to operate for about 5 hours without charging.  

b. After the  

 indicator is ON for several hours without charging or there is no more power in the battery, the scale 

will be powered off automatically. 

c. After battery charging, if there is no display, it indicates that either there is difficulty in battery charging or a damaged 

battery. To prolong the battery life, we suggest you charge the battery after using 48hours or no less than once per week. 

To avoid any damage to the battery, please charge it correctly. Additionally, we suggest you switch off the scale to shorten 

the charging time. The charging lamp on the displaying window and adaptor will turn red during charging. When the 

charging lamp on the adaptor becomes green, it means the battery is fully charged.     

  

PRECAUTION

              

1. Please charge the scale with standard charger. 

2. The load placed on the scale hook must not exceed the maximum weighing capacity of the scale.

3. Perform routine inspection and maintenance to ensure operation safety for these basic items:

 

a) Check for loose bolts.

 

b) Check hook and shackle for deformation, wearing and tearing.

 

c) Check other scale component for signs of metal fatigue.

 

d) Check for missing hook latch.

 

e) Avoid hitting, bumping the display window.

 

f) Do not use the scale in the rain or heavily polluted environment.

 

g) If the scale is not going to be used for some time, please clean it, remove the battery and store it in  

 

 

dry conditions.  

CALIBRATION METHOD

Please do not attempt to calibrate the scale without standard weight

Step

Operation

Display

Remarks

1

Press & Hold [ZERO] 

Key to power on

00000

Input the password “*****”

2

Press [ZERO] to 

confirm

SPAn

Enter into setting state, and make sure the 

scale is with non-load.   

3

Press [HOLD] Key

SEt

00000

It will display “00000” after 5 seconds.

4

Press [HOLD] Key to 

add Press [UNITS] Key 

to move the digit left

3000

Load the scale. The closer to full capacity the 

better.  For example, 3000kg  

5

Press [ZERO] 

HOLd

The scale will record the new calibration data. 

User Manual