background image

7

107299

OWNER’S MANUAL

For convenience and efficiency, install heater

• where there is easy access for operation,

inspection, and service

• in coldest part of room

Figure 4 - Mounting Clearances As Viewed
From Front of Heater

36"

2"

FLOOR

CEILING

Minimum

Minimum to Top 
of Carpeting, Tile,
or Other Combustible 
Material

6"

Minimum
From
Sides of
Heater

Left
Side

Right
Side

INSTALLATION

 WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below:

• external regulator (supplied by installer,

see page 9)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

*  An CSA/AGA design-certified equip-
ment shutoff valve with 1/8" NPT tap is an
acceptable alternative to test gauge connec-
tion. The optional CSA/AGA design-certi-
fied equipment shutoff valve can be pur-
chased from your dealer. See Accessory,
page 18.

LOCATING HEATER

This heater is designed to be mounted on a wall.

 

 WARNING: Maintain the mini-

mum clearances shown in Figure
4. If you can, provide greater clear-
ances from floor, ceiling, and
joining wall.

 WARNING: Never install the

heater
• in a bathroom (Models FB-

10BA and FBS-10BB only. FB-
60BA is allowed in bathroom.
Check local codes.)

• in a recreational vehicle
• where curtains, furniture, cloth-

ing, or other flammable objects
are less than 36 inches from the
front, top, or sides of the heater

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

 CAUTION: If you install the

heater in a home garage
• heater pilot and burner must

be at least 18 inches above
floor

• locate heater where moving ve-

hicle will not hit it

 CAUTION: This heater creates

warm air currents. These currents
move heat to wall surfaces next to
heater. Installing heater next to
vinyl or cloth wall coverings or
operating heater where impurities
(such as tobacco smoke, aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.

IMPORTANT: 

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Fresh Air for Com-
bustion and Ventilation, 
pages 4 through 6.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source.  If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use  this heater
as your primary heating source.

Continued

INSTALLING HEATER TO
WALL

Mounting Bracket

The mounting bracket is located on back
panel of heater. It has been taped there for
shipping. Remove mounting bracket from
back panel.

Mounting
Bracket

Figure 5 - Mounting Bracket

INSTALLING THERMOSTAT
SENSING BULB -

For T-Stat Models Only

Remove clip and bulb from shipping loca-
tion. Place clip and bulb into operation loca-
tion (see Figure 6)

Figure 6 - Moving Thermostat Sensing
Bulb

Содержание FB-60BA

Страница 1: ...lationandservicemustbeperformedby a qualified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions...

Страница 2: ...plianceareaclearand free from combustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance i...

Страница 3: ...ton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY...

Страница 4: ...ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to t...

Страница 5: ...all fuel burning appliances in the space Vent free heater ______________ Btu Hr Gas water heater ______________ Btu Hr Gas furnace ______________ Btu Hr Vented gas heater ______________ Btu Hr Gas fir...

Страница 6: ...ethepowervent VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permane...

Страница 7: ...cloth ing orotherflammableobjects arelessthan36inchesfromthe front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas CAUTION If you install the heater in...

Страница 8: ...walls wall areas between studs or to solid walls concrete or masonry Decidewhichmethodbettersuitsyourneeds Eithermethodwillprovideasecureholdfor the mounting bracket Removing Front Panel Of Heater 1 R...

Страница 9: ...as to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Nevercon...

Страница 10: ...lve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 15 2 Pressurize supply piping system by ei the...

Страница 11: ...e to the PILOT IGN position MANUAL LIGHTING PROCEDURE OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance has a pilot which must be lighted by hand When lighting the pilot follow th...

Страница 12: ...irst time after hook ing up to gas supply If so you may need to press in control knob for 30 seconds This will allow air to bleed from the gas system 6 Release downward pressure on con trol knob and t...

Страница 13: ...to pilot until pi lot lights 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Follow steps 8 and 9 under Lighting Instruc tions page 12 OPERATI...

Страница 14: ...or button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released REMEDY...

Страница 15: ...ew hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local propane LP gas company 3 Observe minimu...

Страница 16: ...2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 13 1 Locate and correct all leaks see Check ing Gas Connections page 10 2 Replace control valve 1 Take apart...

Страница 17: ...on the back page of this manual Send a check for 5 00 payable to DESA International You may have further questions about in stallation operation or troubleshooting If so contact DESA International s...

Страница 18: ...se date Usually we will ask you to return the defec tive part to the factory REPLACEMENT PARTS EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap ACCESSORY Purchase this heater accesso...

Страница 19: ...y W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 www njplaza com ecep Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 www tarantin com Heater Fireplace Store...

Страница 20: ...107299 PROPANE LP GAS HEATER FB 10BA 28 2 28 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 32 2 3 19 17 8 9 22 32 31 26 30 27 23 18 28 29 10 21 20 18 30 25 24 22 17 16 13 1 14 15 7 11 12 33 4 5 7 6...

Страница 21: ...r 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line Assembly 1 19 L98127 02 Lower Gas Outlet Tube Assembly 1 20 L98...

Страница 22: ...22 107299 PROPANE LP GAS HEATER FB 60BA 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 29 2 3 19 17 8 9 29 28 23 27 24 20 18 25 26 10 18 9 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7...

Страница 23: ...trol Knob 1 13 L98029 04 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line...

Страница 24: ...24 107299 PROPANE LP GAS HEATER FBS 10BB 27 2 27 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 14 2 3 20 19 14 12 25 8 11 11 13 10 26 22 20 27 28 13 10 24 23 21 19 21 15 1 16 17 7 18 4 5 7 6 7 7 9...

Страница 25: ...01 Nut 2 11 L98084 01 Screws 2 12 L98010 08 Grill 1 13 L98411 01 Ignitor Line 1 14 L98011 01 Grill Fastener 2 15 L99029 08 Pressure Regulator 1 16 L98801 01 Washer 2 17 L98806 01 Self Tapping Screw 2...

Страница 26: ...o parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper...

Отзывы: