background image

11

105564

OWNER’S MANUAL

TO TURN OFF GAS

TO APPLIANCE

1.

Remove front panel (see Figure 7,
page 8).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 30
seconds after pilot is lit. After 30 sec-
onds, release control knob. Now fol-
low step 9, above.

5.

Replace front panel.

 CAUTION: Do not try to ad-

just heating levels by using the
equipment shutoff valve.

Thermocouple

Pilot Burner

Figure 17 - Pilot

Ignitor Electrode

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information
in column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Press in and turn control knob clock-
wise 

Clockwise

 to the OFF position (see

Figure 16).

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise 

C-clockwise

 to the PILOT/

IGN position. Keep control knob
pressed in for five (5) seconds.

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

6.

Release downward pressure on con-
trol knob and turn clockwise

Clockwise

to OFF.

7.

Press in control knob and turn back
to PILOT/IGN. This will cause the
piezo ignitor to spark and light the
pilot gas. If needed, repeat steps 5
through 7 until pilot lights.

Figure 16 - Control Knob In The OFF
Position (FB-10BA Shown)

Shutting Off Heater

1.

Turn control knob clockwise 

Clockwise

to the PILOT/IGN position.

2.

Press in control knob and turn clock-
wise 

Clockwise

 to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise 

Clockwise

 to

the PILOT/IGN position.

MANUAL LIGHTING

PROCEDURE

OPERATING
HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

NON-THERMOSTAT MODELS
FB-10BA AND FB-60BA

Note: 

If pilot does not stay lit, refer

to Troubleshooting, pages 14 through
16. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot with
match. To light pilot with match, see
Manual Lighting Procedure.

8.

Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 sec-
onds, release control knob. 

Note:

 If pi-

lot goes out, repeat steps 3 through 7.

9.

To light burner, slightly press in con-
trol knob and turn counterclockwise

C-clockwise

. Release downward pressure

on control knob while turning.

Model FB-10BA:

 Set control knob to

desired heating position. 

Note:

 Both

HIGH and LOW are locked posi-
tions. You must press in control knob
before turning it from these positions.

Model FB-60BA:

 When pilot is lit,

turn control knob to ON.

Continued

Содержание FA-10BA

Страница 1: ...ationandservicemustbeperformedby a qualified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions f...

Страница 2: ...in the same room with heater Make sure grill guard is in place before running heater Keeptheapplianceareaclearand free from combustible materials gasoline and other flammable vapors and liquids 1 Thi...

Страница 3: ...on 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY...

Страница 4: ...ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to th...

Страница 5: ...all fuel burning appliances in the space Vent free heater ______________ Btu Hr Gas water heater ______________ Btu Hr Gas furnace ______________ Btu Hr Vented gas heater ______________ Btu Hr Gas fir...

Страница 6: ...hepowervent VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent...

Страница 7: ...ssthan36inchesfromthe front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas CAUTION If you install the heater in a home garage heaterpilotandburnermustb...

Страница 8: ...s or to solid walls concrete or masonry Decidewhichmethodbettersuitsyourneeds Eithermethodwillprovideasecureholdfor the mounting bracket Removing Front Panel Of Heater 1 Remove two screws near bottom...

Страница 9: ...erconnectheater to private non utility gas wells This gas is commonly known as well head gas CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas...

Страница 10: ...supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 14 2 Pressurize supply piping system by ei ther using com...

Страница 11: ...e to the PILOT IGN position MANUAL LIGHTING PROCEDURE OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance has a pilot which must be lighted by hand When lighting the pilot follow th...

Страница 12: ...st time after hook ing up to gas supply If so you may need to press in control knob for 30 seconds This will allow air to bleed from the gas system 6 Release downward pressure on con trol knob and tur...

Страница 13: ...r thermostat model see Troubleshooting pages 14 through 16 GRH OV 007 GOOD PILOT LP MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Light ing Instructions page 12 2 With control knob presse...

Страница 14: ...ignitor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released R...

Страница 15: ...hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local natural gas company 3 Observe minimum inst...

Страница 16: ...Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 13 1 Locate and correct all leaks see Check ing Gas Connections page 10 2 Replace control valve 1 Take apart gas...

Страница 17: ...address listed on the back page of this manual Send a check for 5 00 payable to DESA International You may have further questions about in stallation operation or troubleshooting If so contact DESA I...

Страница 18: ...date Usually we will ask you to return the defec tive part to the factory REPLACEMENT PARTS EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap ACCESSORY Purchase this heater accessory...

Страница 19: ...y W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 www njplaza com ecep Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 www tarantin com Heater Fireplace Store...

Страница 20: ...105564 NATURAL GAS HEATER FA 10BA 28 2 28 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 32 2 3 19 17 8 9 22 32 31 26 30 27 23 18 28 29 10 21 20 18 30 25 24 22 17 16 13 1 14 15 7 11 12 33 4 5 7 6 7...

Страница 21: ...r 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line Assembly 1 19 L98127 02 Lower Gas Outlet Tube Assembly 1 20 L98...

Страница 22: ...22 105564 NATURAL GAS HEATER FA 60BA 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 29 2 3 19 17 8 9 29 28 23 27 24 20 18 25 26 10 18 9 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7...

Страница 23: ...trol Knob 1 13 L98029 03 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line...

Страница 24: ...24 105564 NATURAL GAS HEATER FAS 10BB 27 2 27 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 14 2 3 20 19 14 12 25 8 11 11 13 10 26 22 20 27 28 13 10 24 23 21 19 21 15 1 16 17 7 18 4 5 7 6 7 7 9...

Страница 25: ...Screws 2 12 L98010 08 Grill 1 13 L98411 01 Ignitor Line 1 14 L98011 01 Grill Fastener 2 15 L99029 07 Pressure Regulator 1 16 L98801 01 Washer 2 17 L98806 01 Self Tapping Screw 2 18 L98085 02 Mounting...

Страница 26: ...unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maint...