Serial response and error messages.

Message

SYSTEM_START_3

DSP1 has rebooted

OFF_HOOK

TBU has gone off hook

ON_HOOK

Front panel switch or DC loop has caused TBU to go on hook

+ON_HOOK

K-BREAK has caused TBU to go on hook

*ON_HOOK

Disconnect tone  has caused TBU to go on hook

RING

TBU is ringing

AUTO_ANS

TBU has auto answered a call

E_FR

DAA chip set Framing error

E_LC

Telephone line under or over current fault

E_BF

RS232 Serial buffer full

E_RO

DAA receiver overload

E_IC

An invalid character was sent to the RS232 interface.

E_COM

Communications error with DSP2 or CPLD

POLI

Line Polarity inversion detected

DODI

Line drop out (K-BREAK) detected

Operation

Making a call

Connect the Copper 29 to the telephone line and audio interfaces as required.

Connect a telephone to the 'handset' socket on the rear panel.

Dial the number required using the telephone.

Divert the call to the TBU by pressing the off hook button on the TBU. The telephone will be disconnected and
the call will be diverted to the TBU.

Adjust the level controls as required.

When the call has ended, hang up the TBU by pressing the on hook / off hook button for ~2 seconds.

To answer an incoming call press and release the on hook / off hook button.

Содержание Copper 29

Страница 1: ...GLENSOUND LTD Broadcast Equipment Manufacturers Copper29 GlensoundTelephonebalanceUnit Handbook Issue 6...

Страница 2: ...L E N S O U N D E L E C T R O N I C S L I M I T E D Copper 29 HANDBOOK G Glensound Electronics Ltd 6 Brooks Place MAIDSTONE Kent ME14 1HE Phone 44 0 1622 753020 Fax 44 0 1622 762330 www glensound co u...

Страница 3: ...y 6 Front Panel 6 Metering 6 Gain control 6 On hook Off hook control 6 Power and status indication 6 DIP configuration switches 7 Country selection switch 8 Rear Panel 9 Analogue audio I O 9 Digital a...

Страница 4: ...alogue inputs and two balanced analogue outputs are provided Additionally AES3 inputs and outputs are provided to allow easy interfacing to digital studio equipment Provision has been made for a telep...

Страница 5: ...IVE 2004 108 EC Standards to which conformity is declared Emissions EN 61000 6 3 Immunity EN 61000 6 1 Low Voltage Directive EN 60065 Telephone Network ETSI ES 203 021 I the undersigned hereby declare...

Страница 6: ......

Страница 7: ...Panel Drawings...

Страница 8: ...WORK ECHO CANCELLATION DAA TELEPHONE LINE INTERFACE TELEPHONE LINE LINE DRIVE LEVEL 16 x LINE IMPEDANCE POSSIBILITIES PROCESSOR TO CONTROL ALL SWITCHES AUTO ANSWER ON OFF HOOK CALLS ETC AGC ON OFF FRO...

Страница 9: ...receive metering CPLD The CPLD provides all system clocks and general interface logic Power Supply The Copper 29 TBU is powered by a high reliability mains input switched mode supply This produces a...

Страница 10: ...ble below DIP Switch Settings 1 Network echo canceller enable 2 Acoustic echo canceller enable See note below 3 Auto answer 4 Auto answer period Off 2 rings On 8 Rings 5 DAA full scale Off 0dBm normal...

Страница 11: ...edance etc to be set to the appropriate Telecom standard Switch position Region Country 0 UK 1 CTR21 2 TBR21 3 USA 4 Thailand 5 South Korea 6 Japan 7 Brazil 8 Bulgaria 9 South Africa A Australia B New...

Страница 12: ...DC loop inputs or the RS232 interface The DC loop inputs should be shorted to ground to activate the function described in the table below Remote control interface 15 way D socket DB 15 Pin Direction...

Страница 13: ...sconnect tone mask high word 0x00 0xFFFF AGR 206 nnn Set disconnect tone mask low word 0x00 0xFFFF AGR 207 nnn Reserved AGR 208 n Set acoustic echo canceller state 1 on 0 off AGR 209 n Set line echo c...

Страница 14: ...t to the RS232 interface E_COM Communications error with DSP2 or CPLD POLI Line Polarity inversion detected DODI Line drop out K BREAK detected Operation Making a call Connect the Copper 29 to the tel...

Отзывы: