Page 22 of 27
ADC Clock Source
This control sets what clock source is used as a reference for the ADC. The digital output will
be locked to the selected source. There are 4 options.
A)
Master (The internal clock is used as the reference)
B)
Slave (The external Sync (Word Clock, AES Sync or DAC input) is used as the reference)
C)
Auto (If an external clock is present then this is used as the reference, if not then the
internal clock is used (The frequency of the internal clock can be different to that of the
external clock))
D)
Auto Lock (The external clock is used as the reference. If the external clock is not
present then the internal clock is set to the last known frequency of the external clock)
ADC Master Rate
This sets the output sample frequency of the internal clock. There are 6 options:
A)
44.1kHz
B)
48kHz
C)
88.2kHz
D)
96kHz
E)
176.4kHz
F)
192kHz