![Glendinning CRMA 16 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/glendinning/crma-16/crma-16_installation-and-operation-manual_2231589006.webp)
6
3.7 DC Wire Connection
WARNING:
•
All wiring should be done in ac-
cordance with ABYC
’
s standards. If
you are unsure of these standards,
consult a qualified electrician.
!
!
3.8 Control Switch
•
Mount the control switch near where the cable exits
the side of the boat.
•
Connect red quick connector terminal to the tabs on
the control switch.
The Cordreel comes with (2) 14 gauge wires exiting from
the gear motor cover.
•
These wires should be connected to the 12 or 24
VDC power source depending on unit purchased
(see label on unit for correct voltage).
•
Connect wire to DC battery as shown to left.
•
Make sure all connections are secured and protect-
ed from the environment.
DC Power Input
•
12 or 24v DC Input (check
label on unit)
RED
-
DC Po
BLACK
-
DC Negative
•
use 15amp breaker or fuse
10’
long Control
Switch Wires
Cutout for switch is
1”
x
1.75”