www.gdts.one
DOK4x HOIAO WxDEN · FD 9912
7
Air-to-water heat pump 6 kW
English
4 Transport
4.1 Outdoor unit
A pallet should be used to transport the heat pump to its final
installation location. The outdoor unit can be transported with a
lift truck, hand truck or similar.
Once the side sections have been removed, the outdoor unit
can be lifted by the cover. For this, loosen the two screws at the
top, tilt the metal plate to the side and remove at the top (see
step 1-3)
4.2 Indoor unit
A lift truck is suited for transporting the unit on a level surface.
Carrying straps may be used if the heat pump needs to be
transported on an uneven surface or carried up or down stairs.
These straps can be passed directly underneath the pallet.
To lift from the pallet, the indoor unit can be tilted back by up to
45° and lifted by the handles on the back at the top. Tilting over
45° is not permitted without removing the refrigeration circuit
beforehand.
To remove the refrigeration circuit, remove the side plate at the
bottom right.
The casing panels must be dismantled in the order outlined be-
low.
The bottom side panel must be removed first.
For this, loosen the screws on the bottom side section, turn out
the panel slightly and pull it out to the front (see step 1-3).
Secondly, remove the top side panel.
To do this, loosen the screws, fold out the panel slightly and re-
move the facade panel at the top (see step 4-6).
The front panel can then be removed.
For this, loosen the 4 screws on the frame at the side. Push the
panel approx. 10 mm to the right, then push it forwards slightly
and remove at the top (see step 7-9). Disconnect the connec-
tion cables to the display on the universal hardware interface.
1.
2.
3.
1.
45°
max.
T
ilting dimension 2190
2.
3.
1.
1.
4.
4.
5.
6.
7.
7.
7.
7.
8.
9.
Содержание 06CHOIAOC6
Страница 2: ......