ELECTRICAL INSTALLATION
Electrical wiring must be done by a qualified person(s) in accordance
with all applicable codes and standards. This range hood must be
properly
earth
ed. Turn
off
electrical power at
power board
before wiring.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
INSTALL
ING
THE HOOD
•
C
arefully remove the plastic protective film from all exterior
surfaces
of
the hood and chimney prior to final installation.
•
A
t least two people will be required to mount the hood.
Height over cooktop
Referring to the Australian standard AS/NZ
5601.1:2013 the minimum hood distance
above a cooktop must not be less than 650mm
for gas and 600mm for electric or induction
cooktops.
We suggest a height of 750mm above the
cooktop as a good functional height. Heights over
750mm above the cooker are at the installer's
and user's discretion - understanding that there
may be a loss of extraction efficiency.
1.
Secure the hood mounting bracket to the wall using (3) ST 5 x 45mm
mounting screws and anchors to suit the wall. Align the hood body with the
hood mounting bracket. Gently lower the hood until it securely engages the
bracket.
2.
Fix the discharge collar into the air outlet adapter.
3.
Attach an adequate length of 150mm round duct to the air outlet
adapter. Reducing the outlet diameter
will increase noise levels.
4.
Carefully slide the flue chimney top piece down inside the decorative flue
bottom piece. Carefully place the decorative flue bottom into the recessed
area of the top of the rangehood body.