APPENDIX
APPENDIX B
18 l/min
12 l/min
12 l/min
9 l/min
9 l/min
9 l/min
9 l/min
9 l/min
12 l/min
18 l/min
inlet
595mm
C
D
18 l/min
12 l/min
12 l/min
9 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/min
9 l/min
9 l/min
9 l/min
12 l/min
18 l/min
inlet
55mm
595mm
195 mm
90mm
85mm
85mm
90mm
(hot)
(cold)
Manifolds
Manifold type: 1 - Stock Code MIP 050
(one bathroom, one en suite shower room, one cloakroom, one kitchen)
Flow regulator
(litres/minutes)
Terminal fitting
Hot water
manifold outlets
Quantity
Cold water
manifold outlets
Quantity
18
Bath tap
1
1
9
Hand basin
3
3
12
Kitchen sink
1
1
9
Toilet cistern
None
3
9
Shower
1
1
12
Washing machine
1
1
9
Dishwasher
None
1
Total
7
11
Manifold type: 2- Stock Code MIP 060
(two bathrooms, one en suite shower room, one cloakroom, one kitchen,
one utility room)
Flow regulator
(litres/minutes)
Terminal fitting
Hot water
manifold outlets
Quantity
Cold water
manifold outlets
Quantity
18
Bath tap
2
2
9
Hand basin
4
4
12
Kitchen sink
2
2
9
Toilet cistern
None
4
9
Shower
1
1
12
Washing machine
1
1
9
Dishwasher
None
1
Total
10
15
Two sets of manifolds are available as an
optional extra. Each set comprises a separate
hot and cold water manifold. Both are provided
with a 22mm inlet connection located centrally.
All outlet connections are 15mm compression.
The centre to centre dimension of each branch
is 55mm.
595mm
2 No 6mm
fixing holes
18 l/mm
12 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
12 l/mm
inlet
55mm
18 l/mm
12 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
9 l/mm
12 l/mm
inlet
165mm
595mm
A
(hot)
B
(cold)
blank
blank
The arrangement of each manifold is supplied as
shown. This provides the best balance of flows
but the flow regulators/duty of each branch can
be changed if required as long as a reasonable
balance is maintained. If it is necessary to
change or clean the flow regulator this can be
done without needing to drain the system by
closing the valve and removing the screwed
cover below the white plastic cover.
The manifolds are designed to be used with
plastic pipework and are supplied complete
with isolation valves and flow regulators on
each branch. They would normally be installed
in the same cupboard as the thermal storage
appliance (as shown below) but can be installed
in another cupboard close to the appliance if
required.