Glazing Vision strongly recommends using mechanical lifting aids for all product movements. 
Lifting  frames/eyes  are  provided  with  your  product  installation  package  however  these  will 
remain the property of Glazing Vision. 

 

When using manual handling to manoeuvre products there is also the increased risk of damage 
to them. Glazing Vision will not be held responsible for this as title passes to the client upon 
arrival at their address (see your supplier’s terms and conditions for more information). 

 

Prior to starting installation, check the delivery box or order confirmation for the exact weight 
of the product. 

 

Never install any product showing signs of damage. If in doubt consult Glazing Vision for advice. 

 

Risk of crush and/or trapping injuries. Make sure fingers and other obstructions are clear of the 
product  and  its  mechanisms  at  all  times,  as  severe damage/injury  may  be  caused.  Optional 
extra  proximity  sensors  (to  stop  the  product  moving  if  an  IR  beam  is  interrupted)  can  be 
specified at the time of order, however they do not offer complete coverage, so care must still 
be taken. 

 

There is also overcurrent protection, predominantly for preventing damage to the product and 
its mechanisms. It should never be relied upon to prevent injuries. 

 

Do not touch the motors/mechanisms after operating the unit as they may become hot. 

 

Do not pull on the cables where they exit the product. Doing so will mean that the cables will 
be pulled too tightly and may result in damage to the product and/or create additional work 
during maintenance visits. 

 

Do not allow water to enter the product (eg. do not leave the product open in the rain). This 
could damage the control board and/or mechanisms. If required, a rain sensor can be specified 
at the time of order. 

 

Do not walk or sit on the unit. 

 

Do not place anything on,  or cause obstruction to the moving  sections of the product when 
operating the unit as this may cause damage to the unit’s mechanisms and/or prevent it from 
opening/closing. 

 

Please dispose of the packaging material for this product in an environmentally friendly manner. 

 

Do not attempt to disassemble or repair the product unless suitably qualified. You run the risk 
of causing a fire, malfunction and/or personal injury. 

 

A safe working platform must be provided for any installation/maintenance work carried out. 
This includes suitable edge protection. 

 

Any electrical work should be carried out by a qualified and competent electrician in accordance 
with Glazing Vision’s wiring diagram(s). 

 

Do  not  install  the  circuitry  in  a  damp  place  or  a  place  where  it  may  come  into  contact  with 
water. 

 

Make  sure  that  the  cables  are  not  squashed  or  damaged,  and  do  not  bend  the  cables 
excessively. This constitutes a fire hazard. 

 

Should any cables or electrical components break or become damaged, have them repaired or 
replaced immediately. Deteriorated insulation of electrical parts or overloading may cause an 
electric shock or fire. 

 

Do not allow unauthorised persons (e.g. children) to operate the product as this may lead to 
personal injury or damage to the product. Do not leave children or pets unsupervised near the 
product – it may open/close unexpectedly (eg. due to rain sensor) and cause injury. 

 
For more information or assistance please contact Glazing Vision.  

 

 

Содержание Standard Xvent

Страница 1: ...To help people embrace light air and space GV Standard Xvent Installation Manual...

Страница 2: ...Mills Road Diss Norfolk IP22 4RG Registered in England No 2987024 VAT No 637 7241 26 01379 658300 info glazingvision co uk FM596998 EMS613885 Contents Section Description Page Introduction 3 Safety 4...

Страница 3: ...dalone solo and integrated formats The Xvent has been designed and tested to BS EN 12101 2 2003 A variety of optional extras including a rain sensor thermostat remote control and building management s...

Страница 4: ...ds Clients are wholly responsible for all lifting to get the product to the upstand ready for installation Where the client is going to be using manual handling as a means to move the product into pos...

Страница 5: ...that the cables will be pulled too tightly and may result in damage to the product and or create additional work during maintenance visits Do not allow water to enter the product eg do not leave the...

Страница 6: ...nclosed within the hardware box for each unit you should find at least the following Stainless steel woodscrews Plastic packers various sizes Low modulus silicone 3 Xvents have two coiled cables emerg...

Страница 7: ...r to provide safe access during the installation works It will be necessary to work on the outside and therefore suitable provisions should be made for safe handling of the product including all relev...

Страница 8: ...in until they stop against the base extrusion figure 2 4 Replace the clevis pins through the closest holes in the spreader bar 5 Loosen the adjustment fixings and slide the bracket until it is agains...

Страница 9: ...y lift the product to the roof using strops underneath the wooden build frame spreader bars will be needed Glazing Vision recommends a 1 over 2 spreader arrangement but please consult with your liftin...

Страница 10: ...and top and the majority of the weight still supported adjust the position of the product on the upstand so that the internal framework is equally spaced and aligned with the internal finishes 6 Caref...

Страница 11: ...per the guidelines in the next section as the Xvent is a safety critical product this will need to be done by a Glazing Vision Engineer 13 Follow the Site QC document Interior Finishing Glazing Vision...

Страница 12: ...nt position 140 Figure 8 identifies the screws that should be removed to disconnect the lid from the mechanisms These two screws should be removed from the mechanism on either side of the vent If the...

Страница 13: ...he lid disconnected and secured in the open position some checks are required to proceed First check that the unit is receiving the correct power from the power supply unit PSU Use a multimeter to che...

Страница 14: ...programming port RJ45 see figure 14 on the front side of the Rooflight with the RS485 dongle and using the Configuration Application import the settings of the controller and confirm it is set as an X...

Страница 15: ...96998 EMS613885 1 Open the Xvent via the control switch to 45 2 Close the Xvent from 45 via the control switch 3 Open the Xvent to the 140 fire position using the fire panel 4 Close the Xvent from 140...