Warning: Let the unit rest for at least 24 hours before you start it. The unit 
can be easily moved between rooms, but please note the following:

Installation of the exhaust hose

1) Place the unit near a power outlet. 

2) Attach the rounded fixing clip at the one side of the exhaust hose and the 

square clip at the other side.

3) Attach the flat clip to the fitting opening at the back of the unit. 

4) Put the other side of the exhaust hose to the outside. 

5) Plug the power cord into the outlet (220-240V, 50 Hz).

rear cOVer

frOnT cOVer

OPeraTIOnal Panel

casTOr

GUIDe THe WInD BOX

POWer lIne

SIDE VIEW

FRONT VIEW

REAR VIEW

aIr

 InleT

aIr

 InleT

DESCRIPTION

MAIN AIR CONDITIONER UNIT

HOT -AIR EXHAUST HOSE

HOSE CONNECTOR 

(WINDOW END)

HOSE CONNECTOR 

(AIR CONDITIONER END)

WINDOW KIT

REMOTER CONTROLLER

PART

DRAIN HOSE

Содержание Silence S20

Страница 1: ...Silence S20 S25 S30 S35 English www glaziar com User Manual...

Страница 2: ...ontain an odour 5 Appliance shall be installed operated and stored in a room with a floor area larger than X m 2 X 4 for 5000 Btu h 7000 Btu h 8000Btu h X 7 7 for 9000Btu h 1000Btu h 10500Btu h WARNIN...

Страница 3: ...ision of an individual specified in the use of flammable refrigerants 1 The appliance is for indoor use only 2 Do not use the unit on a socket under repairs or not installed properly 3 Do not use the...

Страница 4: ...nsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can t...

Страница 5: ...years and above and persons with reduced physical sen soty or mental capabilitie or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance...

Страница 6: ...t needs to be repaired In case of breakdown turn off the unit only by the POWER button located on the control panel and contact your dealer If the supply cord is damaged it must be replaced by the man...

Страница 7: ...procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed 1 3 General work area All maintenance staff and others working in the local area shall...

Страница 8: ...e and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to installations using flammable refrigerant...

Страница 9: ...ands etc Ensure that apparatus is mounted securely Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmosphere...

Страница 10: ...e system or isolated by means of shut off valves in a part of the system remote from the leak Oxygen free nitrogen OFN shall then be purged through the system both before and during the brazing proces...

Страница 11: ...ce that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to re use of reclaimed refrigerant It...

Страница 12: ...good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the...

Страница 13: ...housing has no significant effect on the safety Nevertheless it is possible that leaking refrigerant may accumulate inside the enclosure and flammable atmosphere will be released when the enclosure i...

Страница 14: ...on t cause any spark When brazing is required the following procedures shall be carried out in the right order Remove the refrigerant If the recovery is not required by national regulations drain the...

Страница 15: ...should guard the outlet Take special care that drained refrigerant will not float back into the building Evacuate the refrigerant circuit Purge the refrigerant circuit with nitrogen for 5 min Evacuate...

Страница 16: ...equipment using flammable refrigerants See national regulations Storage of equipment appliances The storage of equipment should be in accordance with the manufacturer s instructions Storage of packed...

Страница 17: ...d the square clip at the other side 3 Attach the flat clip to the fitting opening at the back of the unit 4 Put the other side of the exhaust hose to the outside 5 Plug the power cord into the outlet...

Страница 18: ...ool appears on the display Press TEMP or TEMP to adjust the temperature 16 C 31 C Press the SPEED button to adjust the fan speed 4 Dehumidifying mode Press the MODE button until the indicator light sh...

Страница 19: ...rol 1 POWER Power on or off 2 MODE Press the button to select cooling dehumidifying or fan mode 3 TEMP Press the button to increase the temperature 4 TEMP Press the button to decrease the temperature...

Страница 20: ...ir outlet and remove the filter 2 Wash the air filter by submersion into warm water about 40 C with neutral detergent rinse it under running water and dry it with a soft cloth 3 Install air filter car...

Страница 21: ...isconnected or blocked The adjusted temperature is too high Air inlet is blocked by smth Close all windows and doors Remove the heat source Connect or clean exhaust hose Reset temperature adjustment s...

Страница 22: ...ree replacement or repair will be excluded from the prior improper product manipulation Defects on parts and consumables as well as cleaning maintenance or replacement of said parts are therefore char...

Страница 23: ...ocol and may thus contribute to global warming if it is released to the atmosphere Therefore only trained technicians with refrigerant certificate make a filling or emptying Your air conditioner does...

Отзывы: