SIGN FACE
ITEM 1
ITEM 5
ITEM 4
ITEM 3
ITEM 2
Issue 1 February 2005 Stock no. C000/0284
© Copyright February 2005.
A planned maintenance schedule of regular inspection is
recommended, replacing components as necessary.
Replacement components are available direct from GLASDON.
GLASDON cannot be held responsible for claims arising from incorrect
installation, unauthorised modifications or misuse of the product.
®
Rebound Signmaster
TM
Bollard
1)
2)
3)
4)
5)
6)
7)
8)
9)
1)
2)
3)
Glasdon reserve the right to alter specification without prior notice.
INSTALLATION INSTRUCTIONS
Surface Mounting onto an Existing Concrete Foundation
IMPORTANT NOTE: ENSURE ALL RELEVANT PERSONNEL READ THE POINTS LISTED BELOW
AND THAT A COPY IS PASSED ON TO STAFF INVOLVED WITH THE INSTALLATION.
PRODUCT COMPONENTS:
ITEM 1. Bollard
x 1
ITEM 2. Adjustable Concrete-in Fixing
x 4
ITEM 3. Spacer (M10 x 28 mm)
x 4
ITEM 4. Washer (M10 x 50 mm)
x 8
ITEM 5. Fixing Screw (M10 x 100)
x 4
TOOLS REQUIRED FOR INSTALLATION:
6 mm allen key (included within kit)
Equipment to excavate hole
Concrete Mix (Fast Setting)
Spirit Level
SAFETY NOTE: Please refer to the 'Manual handling Operations Regulations 1992'
During the handling of the product and materials used for the installation.
®
Rebound Signmaster
TM
Bollard
INSTALLATION INSTRUCTIONS
Adjustable Depth Concrete-in Fixing System
IMPORTANT NOTE: ENSURE ALL RELEVANT PERSONNEL READ THE POINTS LISTED BELOW
AND THAT A COPY IS PASSED ON TO STAFF INVOLVED WITH THE INSTALLATION.
SAFETY NOTE: Please refer to the 'Manual handling Operations Regulations 1992'
During the handling of the product and materials used for the installation.
®
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
1)
2)
3)
4)
5)
AND REBOUND SIGNMASTER
TM
BOLLARD ARE TRADEMARKS OR REGISTERED TRADEMARKS
OF GLASDON GROUP OR ITS SUBSIDIARIES IN THE U.K. AND OTHER COUNTRIES
PRODUCT COMPONENTS:
ITEM 1. Bollard
x 1
ITEM 2. Anchor Rawl Plug
x 4
ITEM 3. Spacer (M10 x 28 mm)
x 4
ITEM 4. Washer (M10 x 50 mm)
x 8
ITEM 5. Fixing Screw (M10 x 100)
x 4
TOOLS REQUIRED FOR INSTALLATION:
6 mm allen key (included within kit)
16mm Diameter Drill Bit
Appropriate Electric Drill
Hammer
INSTALLATION:
Check for buried services before starting installation.
Prepare a hole 430mm x 430mm x 400mm deep.
Fully assemble and tighten all four Concrete-in Fixings (item 2)
to the base of the bollard (item 1) as shown in the diagram A.
If the depth is restricted to less than 400mm the fixing can be
adjusted by moving the bottom washer of item 2 up the
Concrete-in Fixings and cutting the bar to the desired length.
We would recommend using the same volume of concrete by
increasing the width of the hole accordingly.
Place aggregate and support blocks in the base of the prepared
hole.
Place the Concrete-in Fixing Assembly into the hole ensuring
that the fixings rest on the support blocks and that the bollard
is vertically level.
Remove the bollard and fixing assembly and pour the concrete
mix into the prepared hole to the desired level.
Ensure the bollard is orientated correctly with regard to the site
requirements. (i.e. Retro-Reflective Sign Faces and Amber
Patches).
Fully insert the Concrete-in Fixing Assembly into the concrete
until the base of the bollard is flush with the top surface of the
concrete (see diagram B).
If required the top of the bollard foot detail can be sunk flush
with the concrete/block paving to give a neat finish. DO NOT
concrete over the fixing screw heads as this will impair the
performance of the Rebound models and will prevent the
bollard being replaced.
Ensure the bollard remains vertically level during the concrete
setting period.
REPLACING YOUR BOLLARD
Remove the four Fixing Screws with the 6mm Allen Key
provided (discard the Fixing Screws).
Remove the existing bollard and replace with your new bollard
in the correct orientation aligning the holes in the bollard base
with the existing Anchor Rawl Plugs.
Insert Spacer (item 3) into the four holes in the base of the
bollard.
Position a Washer (item 4) onto the Fixing Screw (item 5) and
insert one into each of the four holes.
Using the 6mm Allen Key provided, loosely tighten each of the
Fixing Screws, and then fully tighten to complete the
installation.
INSTALLATION:
Position the bollard (item 1) centrally on the intended site
and orientate it correctly with regard to the site
requirements. (i.e. Retro-Reflective Sign Faces and
Amber Patches).
Using the bollard, mark out the four hole positions.
Before drilling ensure that the hole centres are a minimum of
100mm from the edge of the concrete foundation.
Drill the four holes with a 16mm diameter drill bit no less
than 80mm deep (ensure holes are in the correct position by
aligning the bollard and drilled hole centres).
Insert an Anchor Rawl Plug (item 2) into each of the four
drilled holes, a hammer may be required to tap them flush to
ground level.
Locate the bollard in position aligning the holes in the bollard
with the Anchor Rawl Plugs ensuring the bollard is
orientated correctly.
Insert Spacer (item 3) into the four holes in the base of
the bollard.
Position a Washer (item 4) onto the Fixing Screw (item 5) and
insert one into each of the four holes.
Using the 6mm Allen Key provided, loosely tighten each of
the Fixing Screws, and then fully tighten to complete the
installation.
REPLACING YOUR BOLLARD
Remove the four Fixing Screws with the 6mm Allen Key
provided (discard the Fixing Screws).
Remove the existing bollard and replace with your new
bollard in the correct orientation aligning the holes in the
bollard base with the existing Anchor Rawl Plugs.
Continue the installation from note 7 above.
400 (MIN DEPTH)
100 MIN
CONCRETE
Diagram B
ITEM 1
ITEM 5
ITEM 4
ITEM 3
ITEM 2
SIGN FACE
ITEM 1
SUPPORT
BLOCK
GRAVEL
CONCRETE
400mm
430mm (MIN WIDTH)
Diagram A
Glasdon U.K. Limited
Preston New Road
BLACKPOOL
Lancashire
FY4 4UL
Tel:
(01253) 600410
Fax:
(01253) 792558
e-mail: [email protected]