The base should be flat, steel float finished, level and square and preferably be raised slightly above
the surrounding ground level.
The concrete base should be a minimum 25N/20mm mix strength equivalent of BS. 5328, Section 2,
Part 10, Grade C25.
Using the supplied unit as a template, drill through all 4 (see detail view A/B) base fixing positions in
each of the feet with a 10mm masonry drill to a minimum depth of 120mm.
Clean drill hole thoroughly using a spiral brush and remove all dust using a blow out pump, airline
or similar.
Insert the self tapping anchor bolts (Item 10) and washer (Item 11) into the drilled hole and tighten
with socket and wrench set.
For optimum fixing performance the following procedure is recommended.
9 of 12
1800m
m
1345m
m
2000m
m
1800mm Overall Table Dimensions
1345mm Fixing Centres
2000mm Concrete Base