background image

-  14  -

Chapter  7.  Operation

7.3  Functional  operation  method

(1)  Battery  check

Push  the  shot  button  slightly  once,  the  battery  status  is  indicated.

(2)  Press  level  adjustment  button  and  press  the  shot  button  to  check  the  number  of 

shot  times  of  the  device.  The  blinking  times  indicate  the  number  of  shot  times.

7.4  Keeping  the  device  after  use

(1)  Open  the  aperture  and  rub  the  surface  of  the  focusing  lens  and  put  the  device  in 

the  case  and  keep  it  under  dry  condition. 

(2)  Keep  the  safe  place  from  vibration  and  electromagnetic  or  physical  shock.

(3)  Please  do  not  open  or  operate  the  device  and  contact  the  customer  center  when 

the  device  appears  trouble.  Please 

7.5  Precautions  before  use

(1)  Do  not  open  the  case  or  handle  the  device  without  skilled  engineer.  It  causes 

trouble  of  the  device.

(2)  Please  read  the  use  manual  or  use  instruction  before  use.

(3)  Light  sensitive  person  should  consult  the  doctor.

(4)  Do  not  draw  into  the  water.  If  the  device  is  dropped  into  the  water  with  POWER 

OFF  status,  dry  with  the  fan  without  power  ON  and  use  but  the  best  way  to  repair  the 

device  is  contact  the  customer  center.

(5)  Please  contact  the  nearest  customer  center  immediately,  if  the  device  is  dropped 

into  the  water  with  POWER  ON  status.

(6)  Please  keep  the  device  away  from  children  even  if  no  possibility  of  danger  from 

malfunction.

(7)  Do  not  use  this  laser  lancet  the  public  place  or  outside.

(8)  Do  not  use  other  than  means  operation.

(9)  If  the  patient  use  other  purpose  of  this  lancet,  the  lancet  will  do  not  work 

properly.

(10)  If  the  temperature  of  surface  lancet  excess  40℃  do  not  use  this  lancet,  as  until 

less  than  39℃.

7.6  Range  of  use

Do  not  use  other  purpose  without  getting  blood  from  finger.

7.7  Emergency  Stop

Please  contact  the  customer  center  immediately,  If  the  device  is  dropped  into  the 

water.

Содержание LUV 01

Страница 1: ...won si Gyeongsangnam do 51140 REPUBLIC OF KOREA Tel 82 55 213 4767 Fax 82 55 213 4767 Homepage www glinc co kr OBELIS S A Bd General Wahis 53 1030 Brussels Belgium Tel 32 2 732 59 54 Fax 32 2 732 60 0...

Страница 2: ...CAUTION 3 Chapter 3 Device symbols Labels Chapter 4 Laser Lancing Device Chapter 5 Performances Chapter 6 Characteristics 6 1 Principle of operation 9 6 2 Electrical rate 9 6 3 Protection type and le...

Страница 3: ...Contents Chapter 8 Routine Maintanance 13 Chapter 9 Trouble Shooting 13 Chapter 10 Supplies Warranty and Customer support 14 Chapter 11 Electromagnetic Compatibility EMC Declaration 15 Chapter 12 Dis...

Страница 4: ...ammable gas mixture or metallic materials 2 Contraindication Its usage is restricted or prohibited on people with hemorrhagic diseases immunization diseases or acute diseases and others those who are...

Страница 5: ...ded condition of use environment This lancet is home appliance 1 6 Caution 1 Keep or use condition see 5 10 this manual 2 Do not have to sterilize and disinfect this lancet 3 Please do not use the out...

Страница 6: ...device is intended for use in collection human blood samples Follow the infection control precautions as directed by your institutional policy 6 Take caution when handing any blood infected waste 7 T...

Страница 7: ...4 Chapter 3 Device symbols Labels MANUFACTURER SERIAL NUMBER REFER MANUAL EXAMINATION AGENCY DIRECT CURRENT WARNING SIGN DATE OF MANUFACTURE KEEP DRY BF TYPE APPLIED PARTS A SECOND TYPE OF EQUIPMENT...

Страница 8: ...Input Battery Lithium Polymer 3 7 V 460 mAh 5V 1 0A Micro USB type GL Inc Toechon dong 82 326 BI CENTER 20 Changwondaehak ro Uichang gu Chang won si Gyeongsangnam do 51140 REPUBLIC OF KOREA OBELIS S...

Страница 9: ...LED Indicate operating status Level Indicator Indicate Battery charging Laser power level and Battery status check Level setting up down button Laser Shoot button Push this button when shot is ready...

Страница 10: ...output 34mJ 10 GL measuring instrument GL T 01 standard 41 000 47 000 Mode Output Level 1 Level 2 Level 3 Level 4 Level 5 ENERGY 84 of Level 5 88 of Level 5 92 of Level 5 96 of Level 5 34mJ 10 41 000...

Страница 11: ...8 2 Humidity 15 to 93 R H 3 Atmospheric Pressure 700hPa to 1060hPa 2 Operation condition 1 Temperature 5 40 2 Humidity 15 to 93 R H...

Страница 12: ...Release Version L1F01 Software program of GL 01 5 12 Degree of protection against the ingress of water Ordinary 5 13 Mode of operation Continuous operation Equipment not suitable for use in the prese...

Страница 13: ...Type B Input AC100 240V 50 60Hz Output DC 5 0V 1A Internal battery is embedded lithium polymer DC 3 7V 460mAh 5 Laser level is selected by button 6 2 Electrical rate 1 Micro USB Charger MICRO USB Typ...

Страница 14: ...arance of the device 2 Open the cap and rub the surface of the focusing lens to remove dust or foreign materials with cotton swab before use 3 Touch once the shot button to check the status of interna...

Страница 15: ...el Level 1 Level 2 Level 3 Level 4 Level 5 Range Infant or children Female Soft finer skin Ordinary person Ordinary person with relatively thicker person Ordinary person thick finger skin Please set t...

Страница 16: ...on for 2 to 3 seconds to power off The power is automatically off if the device is not used for 2 minutes 9 Open the aperture and rub the surface of the focusing lens and put the device in the case an...

Страница 17: ...e read the use manual or use instruction before use 3 Light sensitive person should consult the doctor 4 Do not draw into the water If the device is dropped into the water with POWER OFF status dry wi...

Страница 18: ...15 Chapter 8 Routine Maintenance 8 1 Routine check This device is not required a routine basically Please check only the battery status before use 5 LED shows full charged status...

Страница 19: ...is not operated floating 2 Please contact the customer center even if the device is not restarted when reset button is pushed in this case the device is surely out of order 3 Please change the laser...

Страница 20: ...26 BI Center National Changwon University 20 Changwondaehak ro Uichang gu Changwon city Gyengsangnam do Republic of Korea 10 4 Etc 1 Expected Service Life Approximately 5 years 2 Do not open and break...

Страница 21: ...ndustrial scientific and medical radio frequency equipment EN 55011 Group 1 Class A Medical Electrical Equipment is subject in regard to the electromagnetic compatibility EMC and its special precautio...

Страница 22: ...ypical commercial or hospital environment If the user of the GL 01 requires continued operation during power mains interruptions it is recommended that the GL 01 be powered from an uninterruptible pow...

Страница 23: ...F disturbances are controlled The customer or the user of the GL 01 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipm...

Страница 24: ...sposal of old Electrical Electronic Equipment Application in the European Union and other European countries with separate collection system This symbol indicates that this product shall not be treate...

Отзывы: