SpaceGuard and Safety Mismatch
If a SpaceGuard equipped RCI system detects a mismatch between the primary angle / slew sensors and
the Safety angle / slew sensors, a Safety Mismatch warning is displayed. The mismatch is often related to
the slew count sensors, and slewing the machine back over the reset sensor at 0° of slew may well clear
the fault. If not, inspect the angle sensors for possible mechanical damage. If a fault still exists,
an engineer visit may be required.
Troubleshooting
The 3RCI system continuously monitors the system components for correct operation. In the event that a
problem is detected with the system, the lift capacity is reduced to 700kg and an error message is
displayed next to the
[MENU]
button indicating the nature of the error detected. In the event that more
than one error is present, only the top line error is indicated. Pressing the
[MENU]
button and selecting
the
[MORE]
tab will bring up a list of all detected errors on the system.
Below is a link to the GKD Knowledge base where you can find definitions of all the error codes for the
3RCI System including SpaceGuard.
helpdesk.gkdtechnik.com/kb