M1000002 V1.2 - 11/2021
www.gkdtechnologies.com
10
6 CAN BUS AND PRESSURE SENSOR WIRING
10
6.1
CAN Bus
The CAN bus connections are as follows:
The angle sensor and display connect to a CAN bus. Hi speed CAN bus is provided as an
interface to exchange information within the system and may be used to set-up or monitor
the system using the USB to CAN converter and special Series 1-L PC software.
The Hi-speed CAN is custom programmed during production.
6.2
Pressure Sensor
NOTE: Pressure transducers do not use the same wiring as the CAN bus, where pressure
transducers are being connected, the following applies:
CAN Lo
+V Supply
0V (Ground)
CAN High
CAN Bus M12 Connector
Pin 1 - Brown
Pin 2 - White
Pin 3 - Blue
Pin 4 - Black
+V Supply
Signal 2
0V (Ground)
Signal 1
Single Pressure Switch
Pin 1 - Brown
Pin 2 - N/C
Pin 3 - Blue
Pin 4 - Black