1  X

LUX ‘S’  OUTPUT ONLY:

a) 2 lux to 240 lux. = the approximate

light level at which the ‘S’ output is
activated.

b) 24  HOUR = will operate day and night.

All other outputs operate day and night
irrespective of the ‘S’ output setting.

PULSE COUNT:

The range of the unit will decrease if there is
little difference in temperature between the
moving object and the background.

1  will give a fast response
2  gives better immunity with good

 response

3  gives higher immunity to false

 activation

Timing  1 (2 & 3

 <

 

6 seconds)

TIME 'CCTV' OUTPUT

This is the time in seconds that the 'CCTV'
volt free output will activate after detection.
For setup purposes the respective channel
indicator will also light for this time. Adjust
the jumper link on the RFX-3 Receiver to
select either  normally open in alarm condition
or normally closed contacts.

CUSTOMISING

All factory set parameters can be changed to
suit individual requirements. The highlighted
areas on the programming chart show the
factory settings which suit most applications.
Changes can be easily made either before
installation or on site. Once changes have been
made they are stored in a non-volatile memory.

PROGRAMMING

To amend your existing 'Option' and 'Setting'
1) Press the program button on the detector

once for the number of the required 'Option'
(e.g. range-press twice)

2) Wait 4 seconds until the LED goes out.
3)   Within 5 seconds  press the button  again for

the number of the required  'Setting'
(e.g 20 metres-press three times)

4) The LED blinks twice - the new setting is

saved

To amend any other options/settings repeat
steps  '1'  to  '4'

EXAMPLE - 

To set the Range to 20 metres

a)

Press twice to select Range

b)

Wait until LED goes off (4 seconds)

c)

Press three times for 20 metres

Six

= will flashout your selected settings

Seven

= will reset to GJD factory default settings

Eight/hold = will start the RF continuity test (see page 5)

Nine/hold = will generate and alternative random code ( see page 5)

AU

XI

LI

A

R

Y

OPAL RFX DETECTOR PROGRAMMING CHART

6

5

2

2

2

2

3

3

3

3

4

4

4

5

5

7

8

8

6

7

Press

Twice -set Range

Three -set Lux Level

Four

-set Pulse Count

Five

-set Time 'CCTV'

1

1

1

1

10

15

20

25

35

metres

2

5

15

30

60

120 240 24hr 'S'output

1

2

3

pulse count

0.4

1

2

4

8

25

30

60

seconds

then x
for
then x
for
then x
for
then x
for

OP

T

IO

N

S

wait for indicator to go out

Содержание OPAL RFX

Страница 1: ...ng Heights variable 3 metres high for multi beam coverage 6 metres high for curtain covage and 1 5 metres for pet immunity mask supplied Processing Non volatile memory Intelligentsignalprocessing Digi...

Страница 2: ...CTV 1 2 3 N C N O T 20 55C 12V 35mA N C TAMPER CCTV 3 CCTV 2 CCTV 1 LO A1 A2 A3 S RF1 RF2 RF3 12 13 The RFX 3Receiver monitorstheactive stateofuptothreeOpalRFXpassiveinfra reddetectors The RFX 3 Recei...

Страница 3: ...the receiver and plug into the aerial transmitter in the back of the detector see fig 5 Detectionsignals willbeimmediately transmittedtothereceiver fig 5 Repeat Steps 2 to 6 for each detector To check...

Страница 4: ...before installationoronsite Oncechangeshavebeen madetheyarestoredinanon volatilememory PROGRAMMING Toamendyourexisting Option and Setting 1 Presstheprogrambuttononthedetector onceforthenumberofthereq...

Страница 5: ...d the button down for 5 seconds until the LED goes out then release the button ThenerasethecodefromtheRFX 3Receiver byholdingdownthat channelbutton until thebeepsstop thenrepeatsteps 2 to 6 of the Set...

Страница 6: ...orCCTV applications When mounting higher than boundaryfencesmaskoffanysidebeamsthat falloutsideoftherequireddetectionarea Also ensuring that no obstacles such as walls or large trees for example obstr...

Страница 7: ...LONG RANGE 35 METRE SECTION 6 TO 20 METRES SECTION MULTIBEAM OPTIMUM HEIGHT 3 METRES RANGE MAXIMUM MODULE TILT 0 DEGREE 6 10 20 30 35 9 deg 0 6 TO 20 METRES SECTION TOP MULTIBEAM HEIGHT 6 METRES RANGE...

Страница 8: ...8 InstallationNotes GJD Limited Bolton England 010704 GJD reserve the right to alter the specification without prior notice Tel 01204 363998 Fax 01204 363991 Email info gjd co uk...

Отзывы: