The

has been designed to learn the 'Record'

and 'Stop' commands from most infra-red remote controls.

This forms the basis of a CCTV system using a standard video

recorder working in conjunction with interior or exterior detectors.

The

converts the input signal into infra-red codes.

Inputs less than 5 seconds will produce a 30 second record time.

Inputs longer than 5 seconds will produce a record time equal to

the length of the input signal.

Application notes for controlling a video recorder using the

with other

products are detailed in this leaflet.

Specification:

RED

=

+9 to 15VDC at 6mA standby 20mA operating

BLUE

=

Input - switched negative.

GREEN =

Negative

IR output =

38KHz RC5 coded

The 'MONITOR' lights when an input is present and stays lit for the

duration of the record time.

A contact between 'BLUE' and 'GREEN' will send an infra-red

'RECORD' code when closed and a 'STOP' code when open.

The

is supplied with 1.5 metres of 3-core cable,

a placement pad for secure fixing and a code protection patch.

RED INDICATOR

INFRA RED CODE INPUT

STOP

RED

BLUE

GREEN

RECORD

MONITOR

IR INPUT

LEARN

INFRA-RED

OUTPUT

FIG 1

PLAY

REW

REC

STOP

FF

PAUSE

If the 'MONITOR' flashes for 5 seconds at any point the codes have not

been stored - when the flashing has stopped repeat the procedure.

Ensure the batteries in the remote control are in good condition.

The Learning Procedure should be done in a dimly lit area.

When the power is first applied to the

the 'MONITOR'

will blink three times.

With the Video Remote Control on a flat surface, position the

CLONER 'IR INPUT' approximately 25mm (1") in front of

and at

right angles

to the infra-red emitter on the remote control

(as illustrated)

Press and hold 'LEARN' - the monitor indicator blinks once

and after five seconds lights.

RELEASE THE LEARN BUTTON

The CLONER is now ready to LEARN the codes.

Press the 'RECORD' button * on the Remote Control for one second.

The 'MONITOR' flashes once - storing the 1st code.

* Where two buttons are required for 'record' press the red button first

.......

and then the second button.

Wait until the 'MONITOR' lights.

Press the STOP button on the Remote Control for one second.

The 'MONITOR' flashes twice - storing the 2nd code.

The codes are stored even when the power is removed.

(

1)

(2)

(3)

(4)

Hold typically the 'STOP' button down.

Adjust the position left, right, up and down

to achieve the brightest MONITOR signal.

Release the 'STOP' button keeping the

alignment and position steady.

IMPORTANT:

Alignment must be maintained throughout the learning procedure.