WALK TEST
In walk test mode, the detection LED option is set to ON,
and the pulse count option is set to 1. The detection LED
lights each time the D-Tect 60 detects your presence.
The walk test mode is automatically selected after power
up and cancels automatically after there has been no
detection for 5 minutes. After this the LED will be disabled
unless selected on with switch 3.
Note:
When you conduct a walk test, make sure that the
front cover is in place. Do not conduct walk tests with the
cover removed.
The range of the detector increases without the protective
front cover. Therefore, the front cover must be fitted to
establish the correct beam pattern. Use programming chart
to adjust the range as necessary. Pan and tilt the lens
module over the field of view to obtain the correct coverage
area.
ACCESSORIES
GJD is able to supply the following accessories to aid
installation:
GJD304
Conduit cable entry adaptor ring
PMB1
Pole mount bracket
GJD380
D-TECT walk tester
SPECIFICATIONS
Detection Area
Programmable between 40 & 60 metres
Coverage
60m x 6m coverage max.
Adjustment
180 degree pan + 90 degree tilt
Customised Optics
Double silicon shielded dual element
eliminates 50,000 Lux of white Light
Outputs
Silent solid state magnetically
immune
N/O
N/OPEN
Volt free relay signal contact 24VAC/DC
@ 50mA with an integral 25Ω
Alarm time 5 seconds
N/C
N/CLOSED
Volt free relay signal contact 24VAC/DC
@ 50mA with an integral 25Ω
Alarm time 5 seconds
Pulse Count
1-2
Power Input.
9 to 15 VDC
Current
8mA (12V nominal).
Temp. Compensation
Digital sensitivity adjustment.
Control
Digital microprocessor
Walk Test
Output test mode with LED indication
Operating Temp.
-20 to +55 Centigrade Conformal coated
electronics for increased stability.
Housing
High impact zinc alloy
Protection Rating
IP 65.
Dimensions
145 x 120 x 115 mm.
Weight
750 grams NET, 880 grams GROSS
Mounting Height
Variable
– optimum height 3 metres.
Cable < 200m
Using all 3 outputs (including tamper)
– 8 core 7/0.2mm
Cable < 500m
Using all 3 outputs (including tamper)
– 8 core 16/0.2mm
CE Mark
Содержание D-TECT 60
Страница 3: ...3...
Страница 4: ...4 1 2 3 4 5 6 7 8...
Страница 5: ...5 9 2 6m 60m 10 0m 11 84 28 6m 11 3...