Power Adjust
To adjust the power, first unscrew the sealing cap then adjust the power
potentiometer clockwise to increase the power and counter clockwise to turn it
down. The unit is factory set to maximum output.
Photocell
The photocell is designed to automatically switch the lamps on at dusk and turn
off at dawn. A high degree of hysteresis is incorporated to void on/off switching in
marginal conditions. The unit is factory set at approximately 30 Lux On and 70 Lux
Off, but can be adjusted.
Photocell Sensitivity
To adjust the photocell sensitivity first remove the sealing cap, then adjust the
potentiometer to turn the lamp on when lighting conditions are lighter or darker.
Adjust the counter clockwise to make the lamp turn on when it is lighted and
clockwise when it’s darker.
Disabling the photocell
To disable the photocell, adjust the sensitivity fully counter clockwise. This will make
the lamp turn on at all times.
PoE Models
The Clarius PoE/PoE+ series illuminators are powered by Power over the Ethernet
(PoE) via a network cable connector to a PoE IEEE802af/IEEE802at compliant
switch.
The power consumption of the illuminators comply with PoE IEEE802af and
IEEE802at.
These illuminators are not supplied with a power cord. Instead, they are supplied
with a 2.5m (8’) long network cable. At the end of the network cable is a female
RJ45 Cat5e compliant connector with an IP68 rated cover.
The IP68 rated cover is supplied with the illuminator. Follow the instructions supplied
with the cover on how to attached if to the male Cat5e network cable.
ENSURE THAT THE IP68 RATED COVER IS CORRECTLY FITTED AND ATTACHED TO THE
NETWORK CABLE. IF THIS IS NOT FITTED CORRECTLY MOISTURE CAN GET INTO THE
CONNECTOR AND MAY CAUSE THE UNIT TO MALFUNCTION. THIS WOULD VOID THE
WARRANTY ON THE PRODUCT.
Power and Control Cable Connections
Use suitable IP66 rated enclosure and terminal block for connection
conforming to EN60998-2-1 or EN60998-2-2
Recommended PSU
IS / IM , VS/VM : 24V 30W (ALT-30-24)
IL / IX , VL/VX : 24V 60W (ALT-60-24)
Use only with Class 2 power supply.
SELV Power supply should be approved to relevant EN Safety standards.
SELV Power Supply should be used with devices to protect against short
circuits and overload.
Remote Switching
The Illuminator may be activated remotely by a volt-free contact latched across
the telemetry wires (see Diagram above).
Photocell following contact
Volt-free relay contact-normally open (day) to normally closed (night). See
Diagram above.
Trouble Shooting
Ensure all tests are undertaken by a qualified, trained engineer and
ensure safe working practices are followed at all times.
Step 1: Basics
•
Check power connection
•
Ensure power is 12-32V DC / 24V AC 50-60Hz
•
Check the photocell is working - cover photocell ,light should turn
on
•
Ensure power supply is suitably rated to product - check the
specifications
Step 2: Lamp Test
•
Check current draw of lamp corresponds to specification
•
Check current of lamp - see instructions for correct current settings
To check lamp current ve (red) lead from power supply and
connect a multimetre (set to 10A) in line with the lamp. (One lead of
multimeter in common (COM) other lead into 10A socket of multimeter;
set multimeter to read Amps). Refer to PSI Specifications for correct
current settings.
Step 3: Set up Camera, lens and Illumination
•
Check alignment of lamp
•
Check camera lens- fully open at night and set correctly
•
Check model number to performance specification to ensure
required distance is achievable
Step 4: Call for further assistance
If the lamp is still not delivering the required performance, please
contact Technical Support for further assistance
Note down:
•
Model number and serial number of illuminator
•
Camera make and model
•
Lens make and model
mount
Pot for photocell
adjustment
Pot for power
adjustment
Pressure relief
valve
Power and
control cable
White. Volt Free / Night Switching (N/O)
Yellow. Volt Free/ Night Switching (COM)
Green Telemetry -
Blue Tel
SELV
PSU
MAINS
INPUT
Camera
Day/Night switching
(60V, 0.2A)
External circuits used for interfacing with the illuminator (Camera Day/Night
switching and Telemetry) should be reinforced/double insulated from mains.
Safety Warning
•
When the lamp is running, it is hot to touch. before touching switch off
the illuminator and allow to cool for a minimum of 10 minutes.
•
The illuminator should be positioned so that prolonged starring into the
illuminator at a distance closed than 1m is not expected.
•
The light source of this illuminator is not replaceable, when the light
source reaches its end of life the whole illuminator should be replaced.
•
If the flexible power cord of the illuminator is damaged it should be
exclusively replaced by an authorised service agent.
•
This equipment is not suitable for us in locations where children are likely
to be present.
Certifications
This product complies with the European Directive 2014/30/EU
Electromagnetic Compatibility and 2014/35/EU Low Voltage Directive by
meeting the following standards:
CE-EMC
EN 61547
(Lighting-Immunity)
EN
55015
(Lighting-Emission)
EN
62493
(Lighting
-EMF)
EN
50130-4
(Alarm-EMC)
CE-LVD
EN
60598-1
(Luminaires-General)
EN
60598-2-1
(Luminaires)
Safety
EN 62471 Risk group 2
(LED safety)
Environmental
IEC/EN 60529
IP66
EN50130-5 (Alarm-environmental)
USA
FCC, Class B
AUS
RCM (AS/NZS CISPR 22 Class B)
WEEE:
Waste Electrical & Electronic Equipment European
directive
202/96/EC
RoHS:
Restriction of Hazardous Substances European
directive
202/95/EC
This symbol on the product means that the electrical and/or electronic
equipment to which it relates should be disposed of at the end of life
separately from domestic household waste.
There are separate collection systems for recycling in the EU. For more