9 Maintenance and Cleaning
9.1
Checking Heat Dissipation
If the inverter regularly reduces its output power due to high temperature, please
improve the heat dissipation conditions. Maybe you need to clean the heat sink, or look
for other obstructions.
9.2
Cleaning the Inverter
If the inverter is dirty, shut down the inverter, then clean the enclosure lid.
9.3
Checking the DC switch
Check for externally visible damage and discoloration of the breaker, and the cables at
regular intervals. If there is any visible damage to the breaker, or visible discoloration
or damage to the cables, contact the installer.
Once a year, turn the rotary switch of the DC switch from the On position to
the Off position 5 times in succession. This cleans the contacts of the rotary
switch and prolongs the electrical endurance of the DC Disconnect.
10 Decommissioning
10.1
Dismantling the Inverter
1
Disconnect the inverter as described.
2
Remove all connection cables from the inverter.
3
Screw off all projecting cable glands.
4
Lift the inverter off the bracket and unscrew the bracket screws.
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has cooled down.