Table 7.3f: MM10K Current Draw and Thermal Dissipation specifications
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
MM10K
Level Load Rated Power
Line Current *2) Watt *1) Thermal dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr k Cal/hr
0 0 0 0 0
Power on, Idling 139 0 139 475 120
Pink noise
(1/8th rated
power)
16
/ Ch. 660 x 4
32
/ Bridged 1320 x 2
8
/ Ch. 1300 x 4
16
/ Bridged 2600 x 2
4
/ Ch. 2100 x 4
8
/ Bridged 4200 x 2
2
/ Ch. *4) 2500 x 4
4
/ Bridged *4) 5000 x 2
10.7 5.6 732 330 402 1371 345
Amp (I) Watt
16.9 8.8 1224 650 574 1958 493
25.9 13.5 1914 1050 864 2949 743
32.2 16.8 2414 1250 1164 3973 1001
Pink noise
(max power)
*3)
16
/ Ch. 660 x 4
32
/ Bridged 1320 x 2
8
/ Ch. 1300 x 4
16
/ Bridged 2600 x 2
4
/ Ch. 2100 x 4
8
/ Bridged 4200 x 2
2
/ Ch. 2500 x 4
4
/ Bridged 5000 x 2
13.6 7.1 1143 880 263 897 226
22.4 11.7 2096 1733 363 1238 312
30.0 16.0 2377 / 2455 1466 / 1542 910 / 914 3107 / 3118 783 716
30.0 16.0 2237 / 2291 1099 / 1145 1139 / 1146 3886 / 3911 979 / 985
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Twist lock
*1) The amplifier's PSU operates as a non-resistive load, so the calculation Volts x Amps = Watts would not be correct. Instead, measured and specified here
is what is known as the Active Power of the amplifier providing useful, real-world values of power consumption and heat dissipation.
“
”
“
”
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily
in excess of max. Ratings.