39
EN
USER MANUAL
GI400 / GI410
10. DSD MEMORY IP54 / IP65 / IP68
It is possible to increase the operation of the weight indicator with the additional plate that performs the function of FISCAL MEMORY; It
consisted in filing all the weight values transmitted to a computer for a subsequent processing or integration of the data transmitted by the COM
serial channel.
Each archived value is associated with an ID code. The stored value can be consulted in the display of the indicator using the ID. (As control with
respect to data printed by the PC).
The fiscal memory can store a maximum of 400 000 weighings, after which, it re-writes on the heavy number 0.
With the serial command “PID” or via the key
, the scale number, the gross weight, the tare weight and an ID that unequivocally identifies the
weighing is sent, only in case the platform is
stable and the gross weight is not negative.
The ID have the following format:
<Unique code number>, <Number of weight>
Unique code number: 5 digit number ranging from 0 to 99.999, indicative number of complete single code of fiscal memory.
The fiscal memory can store a maximum of 400 000 weights, after which the weighing number starts again by 00000 and the unique code number
is incremented one at a time.
The weighing relative to an ID can be verified only if:
Has a unique code number equal to the current one in the fiscal memory and a weighing number less than or equal to the last value received with
the “PID2” command.