4.5. ETL certified models. Specific values for models with gas heating
4.5.1. Heating data
ETL CERTIFIED MODELS – GAS HEATING
UNIT
ED260
ED340
ED460
ED660 ED1250
Natural
gas
Injector diameter
mm
in
3.4
(0.13)
3.6
(0.14)
4.4
(0.17)
4.8
(0.19)
4.0
(0.16)
Burner Pressure
mbar
17.4
Rating
BTU
70480
79575
117467
147781
323915
Propane
LPG
Injector diameter
mm
in
2.30
(0.09)
2.50
(0.10)
3.00
(0.12)
3.30
(0.13)
2.6
(0.11)
Burner Pressure
mbar
27.4
Rating
BTU
70480
79575
117467
147781
232915
4.5.2. Details of gas connection
ETL CERTIFIED MODELS – GAS HEATING
ED260
ED340
ED460
ED660 ED900 ED1250
Natural gas and
Propane gas
BSP
male thread
1/2 in
1/2 in
1/2 in
1/2 in
3/4 in
3/4 in
4.5.3. Electric power and consumption. Machines with gas heating
ETL CERTIFIED MODELS – GAS HEATING
VOLTAGE
(50/60Hz)
ED260
ED340
ED460
ED660
Maximum
electrical power
200…240
1Ph+N
2Ph
kW
0.9
0.9
1.6
1.6
Total nominal
consumpt.
200…240
1Ph+N
2Ph
A
4.6
4.3
7.8
8.2
VOLTAGE
(50/60Hz)
ED1250
Maximum
electrical power
200…240
3Ph
kVA
2.2
440…480
3Ph
kVA
2.2
Total nominal
consumpt.
200…240
3Ph
A
6.6
440…480
3Ph
A
3.0