WARNING!   PRODUCT DAMAGE

 

 

• Freezing of the internal pipes and Heat Exchanger of the Model GSWH-1 water heater will result  

 

   in severe damage not covered by warranty. For this reason it is not advisable to use the GSWH-1  

 

   in the winter unless the RV is manufactured for use in the winter and equipped with the Winter  

 

   Use  Device.   Consult  your  OEM and  or  dealer   for additional   information.

 

 
 

 
 

 

 
 

 

CRITICAL INSTALLATION WARNINGS

 

 

• Installation and service must be performed by a qualified installer or service agency. 

 

   This product  is not  designed   for Do-it-Yourself Installation.

 

    • Install 

ONLY

 in recreation vehicles (RV’s) that are manufactured and properly insulated for  

 

 

 

 

 

use in areas where the risk of freezing temperatures are likely. RV’s are recreation vehicles  

 

 

 

 

 

designed as temporary living quarters for recreation, camping, or travel use having their  

 

 

 

 

 

own  power  or  towed  by  another   vehicle.  This Winter  Use  Device  is 

NOT 

designed for use

 

 

 

 

 

with any other  appliance  or product.

 

 

 

• 

DO NOT

 modify  the Winter Use Device in any way. This is dangerous  and  will void the  warranty.

 

 

 

USA AND CANADA - FOLLOW ALL APPLICABLE STATE AND LOCAL CODES

 

 

IN THE ABSENCE OF LOCAL CODES OR REGULATIONS REFER TO CURRENT 
STANDARDS  OF:

 

 

• Recreational Vehicles ANSI A119.2/NFPA 501C.

 

• CSA standard Z240 RV Series, Recreational Vehicle.

 

• Park Trailers A119.5

 

• National   Fuel  Gas  Code  ANSI Z223.1 and/or CAN/CGA B149  Installation Codes

 

• Federal Mobile Home Construction & Safety Standard, Title 24 CFR, part 3280, or   

 

 

   when this Standard is not applicable, the Standard for Manufactured Home Installations    

 

   (Manufactured Home Sites, Communities and Set-Ups), ANSI A255.1 and/or CAN/  

 

 

   CSA-Z240   MH Series,   Mobile  Homes.

 

• National  Electrical   Code  ANSI/NFPA No. 70 and/or  CSA C22.1

 

Содержание WUD

Страница 1: ...ion and service must be performed by a certified installer or service agency The WUD is certified for use with the Girard Tankless Water Heater System in RV s constructed for use where freezing temper...

Страница 2: ...These instructions must be followed exactly or a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the...

Страница 3: ...s designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle This Winter Use Device is NOT designed for use with any other appliance...

Страница 4: ...low 38 F This will cause the unit to automatically light for a short period of time IFthe GSWH 1 SWITCH is set to the ON position the system is POWERED with 12VDC the PUMP must be ON GAS is available...

Страница 5: ...ed if the RV is not in use and or in storage C Components The WUD device consists of two components 1 a Thermostat and 2 a Solenoid 1 Thermostat A thermostat mounted on the Heat Exchanger of the water...

Страница 6: ...it must be plumped properly to function correctly Consult your OEM for the location if installed at time of production Note In certain aftermarket installations access to the fresh water tank may not...

Страница 7: ...nty For this reason it is not advisable to use the unit in the winter unless the RV is manufactured for use in the winter and equipped with this option Consult your OEM for additional information WARN...

Страница 8: ...ing department if you have any additional questions regarding your specific installation application Plumbing Installations CRITICAL INSTALLATION WARNINGS The Solenoid Valve must be located where it i...

Страница 9: ...the Water heater to the location of the SolenoidValve and connect to the RED wire on the Solenoid Valve The current draw of the valve at 12VDC is less than 350mA 12V or Mode SW Cold Hot Hl lo Gromd Ro...

Страница 10: ...will run for approximately 45 seconds NOTICE The RV can provide a sufficient supply of fresh water The water heater is adequately powered with 12VDC and switched ON The RV Water pump is switched ON an...

Страница 11: ...etien doivent tre effectu s par une agence de service ou un installateur qualifi Le DUH est certifi pour une utilisation avec le syst me de chauffe eau sans r servoir de Girard con u pour tre utilis o...

Страница 12: ...ie une explosion ou m me la mort AVERTISSEMENT INCENDIE OU EXPLOSION AVERTISSEMENT Ne pas respecter ces instructions risque d entra ner un incendie ou une explosion et des d g ts mat riels des blessur...

Страница 13: ...s comme r sidence temporaire pour les vacances le camping ou les voyages ils peuvent tre autopropuls s ou remorqu s par un autre v hicule Ce dispositif d utilisation hivernale N est PAS con u pour tre...

Страница 14: ...s allumera automatiquement pour une courte p riode SI l INTERRUPTEUR du mod le GSWH 1 est la position ON En marche si le syst me est ALIMENT en courant continu 12V la pompe doit tre allum e s il y a d...

Страница 15: ...itif d utilisation hivernale si le VR n est pas utilize ou s il est entrepos C Composantes Le DUH comporte deux composantes 1 un thermostat et 2 une valve lectromagn tique 1 Thermostat Un thermostat i...

Страница 16: ...otre fabricant d quipement pour conna tre l endroit si elle est install e au moment de la fabrication Remarque Dans certaines pi ces de rechange installations acc s dans le r servoir d eau douce neser...

Страница 17: ...d d utiliser l unit en hiver moins que le VR soit con u pour l utilisation hivernale et quip de ce dispositif Consulter votre fabricant d quipement pour obtenir de plus amples renseignements AVERTISSE...

Страница 18: ...roducts LLC pour les questions concernant l installation de l appareil Installation de la plomberie AVERTISSEMENT IMPORTANT D INSTALLATION La vanne lectromagn tique doit tre situ e o elle est facileme...

Страница 19: ...vanne electromagnetique et raccorder le filROUGE aIavanne electromagnetique Lacharge decourant de Iavannea t N CC est moins de 350mA Diagramm11 d11 cJblag11 duOlJH 12V31avanne 12V ou 12 vmise aIa ll m...

Страница 20: ...au est ad quatement aliment par du courant 12V CC et que l interrupteur est la position En marche La pompe eau du VR est en marche et fonctionne bien Il y a suffisamment de gaz propane liquide dans le...

Отзывы: