9/26/17 

sMart 

Vent™ 

Owner’s Manual 

GS09086 to GS10007 (GEN. 1) 

GS07980 to GS08060 (GEN. 2) 

  

 
 

 
 

The sMart Vent

™ protects intermediate bulk containers (IBCs) against excessive 

pressure and vacuum buildup. Engineered for low maintenance and easy cleaning, this 

vent offers superior protection for metal IBCs. Additional features include manual 

venting that can be achieved with a press of the hand. 

 

Patent Number 8, 561, 637 

 

 

Содержание sMart Vent

Страница 1: ...otects intermediate bulk containers IBCs against excessive pressure and vacuum buildup Engineered for low maintenance and easy cleaning this vent offers superior protection for metal IBCs Additional f...

Страница 2: ...chnical Data 3 Exploded View of Product 4 8 Safety 8 General Safety Information 9 Product Storage 9 Product Handling 9 Disposal Requirements 9 Installation Instructions 10 Operation Instructions 10 Ma...

Страница 3: ...structed of corrosion resistant 316 stainless steel 3 Standard Tef O Sil Teflon encapsulated O Ring seals are compatible with all ladings for packing groups 1 2 4 Relieves pressure at 3 5 5 or 10 PSIG...

Страница 4: ...009 sMart Vent Revision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 4 Exploded View of Product sMart Vent 5 PSIG Generation 1 Pressure Vacuum Relief Vent GS10005 GS...

Страница 5: ...QF 830 009 sMart Vent Revision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 5 Exploded View of Product sMart Vent 5 PSIG Generation 1 Vacuum Only Relief Vent GS10004...

Страница 6: ...F 830 009 sMart Vent Revision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 6 Exploded View of Product sMart Vent 5 PSIG Generation 1 Pressure Only Relief Vent GS10006...

Страница 7: ...009 sMart Vent Revision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 7 Exploded View of Product sMart Vent 5 PSIG Generation 2 Pressure Vacuum Relief Vent GS07982 GS...

Страница 8: ...0 009 sMart Vent Revision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 8 Exploded View of Product sMart Vent 5 PSIG Generation 2 Pressure Only Relief Vent GS07983 GS0...

Страница 9: ...this manual to avoid injury Product Storage Temperature Range 40 F to 250 F Humidity Range N A Altitude Range N A Store device upright and in its original container to maintain a dust free environment...

Страница 10: ...nually vent pressure This safety relief valve opens and reseats automatically Maintenance Instructions Warning This device is under pressure that could cause injury Do not attempt to disassemble this...

Страница 11: ...60002 3 in 1 combination IBC spanner wrench to unscrew the sMart Vent from its port 2 Remove GS10008 retaining ring Warning the sMart Vent cover is under pressure To prevent injury the sMart Vent cove...

Страница 12: ...pment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 12 3 Remove the GS10009 sMart Vent cover carefully as it may still be under pressure from the pressure spring 4 Remove the pressure poppet s...

Страница 13: ...evision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 13 Ignore steps 5 8 for pressure only sMart Vent 5 Remove the GF39010 lock nut from the vacuum poppet 6 Remove th...

Страница 14: ...sMart Vent Revision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 14 7 Remove the vacuum poppet assembly from the lower housing assembly 8 Remove and replace the vacu...

Страница 15: ...el A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 15 Ignore steps 9 10 for vacuum only sMart Vent 9 Remove the pressure poppet from the lower housing assembly 10 Remove and r...

Страница 16: ...nt Revision Level A Girard Equipment Inc GS09086 to GS10007 GEN 1 GS07980 to GS08060 GEN 2 16 11 Remove and replace the body O Ring from the lower housing if required 12 Re assemble following steps 1...

Страница 17: ...rt Vent may set between 4 6 PSIG Close air supply off and wait for valve to reseat and hold pressure for 30 seconds For example a 5 PSIG sMart Vent may reseat between 3 2 6 PSIG Troubleshooting Repair...

Страница 18: ...ssure O Rings FDA TEF O SIL TEF O SIL VITON A VITON VITON A FDA EPDM GS10122 GS10021 GS10076 GS10098 GS10112 GS10142 Vacuum O Rings FDA TEF O SIL TEF O SIL VITON A VITON VITON A FDA GS10124 GS10020 GS...

Страница 19: ...o be free from defects and will be replaced free of charge if failure occurs within 1 year of date of shipment provided that these parts have been used in accordance with seller s recommendations Our...