Smoke Detector 

Installation Instructions 

 

 

Smoke Detector 

01/98 

Page: 4 of 5 

Operating and Warning Signals 

Signal Detector 

status 

Loud alarm tone at intervals 
Red LED flashes 

Local smoke alarm 

Loud alarm tone at intervals 
Red LED does not flash 

External smoke alarm;  
the detector is repeating an alarm from another 
smoke detector (only with networked by type 
Relay/Networking detectors) 

Brief uniform beep tone at intervals of 40...50 
seconds, with the red LED flashing 
simultaneously 

Battery low-power indicator 
The battery must be replaced 

Brief uniform beep tone at intervals of 40...50 
seconds, with the red LED flashing out of phase 

Smoke detector system fault  
(clean detector or replace it) 

Red LED flashes briefly at intervals of 40...50 
seconds 

The integral self-test is being carried out  
Normal operating condition 

 
 

Maintenance and Care 

To ensure proper functioning of the smoke detector, routine maintenance should be carried out at 
intervals of about 6 months. Proceed as follows: 

  Remove the smoke detector from ist base and clear away the dust (do not use compressed air). 

  Wipe the smoke detector with a damp cloth. 

  Reinsert the smoke detector in ist base and turn it clockwise until it clicks into place.  

  Change the battery if the low-power signal is given (see operating and warning signals). 

  Only use 9 V rectangular batteries type ICE6 LR61. 

Caution! Do not use rechargeable batteries.

 

  Varify that the integral self-test is carried out (see operating and warning signals). 

  Replace smoke detectors after about 10 years of service. 

 
 

Technical data 

Type 

: optical smoke detector 

Enclosure : 

polymer 

Operating voltage 

: 9 V 

Battery type 

: Rectangular battery Type ICE6 LR61, 9 V 

Quiescent current 

: < 8 

μ

Signals 

: See operating and warning signals 

Type Relay/Networking detector only 

: NO contacts 

Alarm output to external signal devices/ 

  max. current, volt-free: 30 V, 1 A 

central alarm sytem 

Ambient temperature for service 

: + 5 to + 40 °C 

Dimensions 

: see Fig. 2 

Weight (without battery) 

: 114 g 

Storage temperature (without battery) 

: - 5 to + 60 °C 

 
 
 