GIRA
Info
Smoke Detector
Installation Instructions
Smoke Detector
01/98
Page: 4 of 5
Operating and Warning Signals
Signal Detector
status
Loud alarm tone at intervals
Red LED flashes
Local smoke alarm
Loud alarm tone at intervals
Red LED does not flash
External smoke alarm;
the detector is repeating an alarm from another
smoke detector (only with networked by type
Relay/Networking detectors)
Brief uniform beep tone at intervals of 40...50
seconds, with the red LED flashing
simultaneously
Battery low-power indicator
The battery must be replaced
Brief uniform beep tone at intervals of 40...50
seconds, with the red LED flashing out of phase
Smoke detector system fault
(clean detector or replace it)
Red LED flashes briefly at intervals of 40...50
seconds
The integral self-test is being carried out
Normal operating condition
Maintenance and Care
To ensure proper functioning of the smoke detector, routine maintenance should be carried out at
intervals of about 6 months. Proceed as follows:
•
Remove the smoke detector from ist base and clear away the dust (do not use compressed air).
•
Wipe the smoke detector with a damp cloth.
•
Reinsert the smoke detector in ist base and turn it clockwise until it clicks into place.
•
Change the battery if the low-power signal is given (see operating and warning signals).
•
Only use 9 V rectangular batteries type ICE6 LR61.
Caution! Do not use rechargeable batteries.
•
Varify that the integral self-test is carried out (see operating and warning signals).
•
Replace smoke detectors after about 10 years of service.
Technical data
Type
: optical smoke detector
Enclosure :
polymer
Operating voltage
: 9 V
Battery type
: Rectangular battery Type ICE6 LR61, 9 V
Quiescent current
: < 8
μ
A
Signals
: See operating and warning signals
Type Relay/Networking detector only
: NO contacts
Alarm output to external signal devices/
max. current, volt-free: 30 V, 1 A
central alarm sytem
Ambient temperature for service
: + 5 to + 40 °C
Dimensions
: see Fig. 2
Weight (without battery)
: 114 g
Storage temperature (without battery)
: - 5 to + 60 °C