Behaviour on voltage return
On
Off
Last value
Configured brightness
Basic setting: Off
Defines the behaviour of the
output after voltage return.
Manual saving of the scene
values
On, Off
Basic setting: On
Disables the saving of the
current actuator state (On/Off)
as scene value in an actuator
for a command via a
transmitter.
Timer behaviour, voltage
return
Off
Restart
Basic setting: Off
Specifies whether the timers
for switch-on delay, switch-off
delay and run-on time remain
off after voltage return or
whether they restart. Directly
connected to the parameters
"Switch-on delay", "Switch-off
delay" and "Run-on time".
Switch-off warning
On, Off
Basic setting: Off
If the switch-off warning is
active, the light is not switched
off directly. The light goes off
30, 15 and 6 seconds before
permanent switch-off. During
the switch-off warning, a
switch-on telegram effects
direct switch-on. It is not
possible to terminate the time
using a switch-off telegram.
Priority, lock-out protection
0...4
Basic setting: 1
Specifies the priority for
recalling and removing a
scene of type Lock-out
protection for the channel.
Priority, restraint
0...4
Basic setting: 2
Specifies the priority for
recalling and removing a
scene of type Restraint for the
channel.
Priority, wind alarm
0...4
Basic setting: 3
Specifies the priority for
recalling and removing a
scene of type Wind alarm for
the channel.
Priority, sun protection
0...4
Basic setting: 0
Specifies the priority for
recalling and removing a
scene of type Sun protection
for the channel.
Priority, twilight
0...4
Basic setting: 0
Specifies the priority for
recalling and removing a
scene of type Twilight for the
channel.
32581212
10499450
09.05.2016
9/11
eNet
Wireless switching/momentary-contact actuator, 1-gang Mini, Wireless
switching/momentary-contact actuator, 1-gang Mini, zero-voltage