background image

3

Setting up energy profile

Condensation water opening

Before mounting the energy profile, open the 
condensation water drain on the bottom of the 
profile base. For this purpose, knock out the 
opening (see arrow) and remove the burr with a 
file.

The energy profile is fastened with only one bolt. 
Depending on the conditions of the foundation, 
there are two options for anchoring the energy 
profile to the ground.

With an underground tube

The energy profile is set up using the 
underground tube on loose or soft ground, e.g. in 
flowerbeds or on grass.

1. Dig a hole approx. 50 cm deep at the 

intended mounting site.

2. Guide the cables through the underground 

tube and cement the tube in vertically and 
flush with the surface.

3. Guide the cables through the profile base.
4. Mount the profile base to the underground 

tube with the accompanying hexagon bolt.

5. Guide the cables into the accompanying 

conduit boxes and connect the plastic-
sheathed cables which reach the device 
units. 

6. Connect the lighting element (if present) 

(see Page 5).

7. Connect the earth cable of the energy profile 

to the earth terminal of the profile base.

8. Place the energy profile on the profile base 

and fasten it with the three Allen bolts 
(M6 x 14).

9. For energy profiles with a lighting element, 

insert the light and close the profile with the 
cover.

Attention

The installation and assembly of electrical 
equipment may only be performed by a qualified 
electrician.

Position of the underground tube

Note the position of the energy column when 
cementing in the underground tube It can be 
aligned by max. 20° on the underground tube.

i

Profile with no lighting element

For profiles with no lighting element, all devices 
and TX_44 cover frames must be mounted 
before the profile cover is set in place. To keep 
the profile splash-resistant, the top edge of the 
TX_44 cover frame must be flush with the top 
edge of the profile.

Содержание 1345 26

Страница 1: ...g Instructions Energy profile with three empty units height 491 mm 1345 26 28 Energy profile with lighting element and three empty units height 769 mm 1349 26 28 Energy profile with six empty units height 769 mm 1351 26 28 ...

Страница 2: ... e g in an entrance area The Gira energy profile is available in different versions in the colours anthracite and aluminium Examples Energy profile with three empty units height 491 mm Order No 1345 26 28 Energy profile with lighting element and three empty units height 769 mm Order No 1349 26 28 Energy profile with six empty units height 769 mm Order No 1351 26 28 Device presentation Here the ene...

Страница 3: ...n bolt 5 Guide the cables into the accompanying conduit boxes and connect the plastic sheathed cables which reach the device units 6 Connect the lighting element if present see Page 5 7 Connect the earth cable of the energy profile to the earth terminal of the profile base 8 Place the energy profile on the profile base and fasten it with the three Allen bolts M6 x 14 9 For energy profiles with a l...

Страница 4: ... Fit the inserts with the accompanying sealing pans The profile has markings to which the supporting rings of the device can be aligned This ensures that the frames are inserted later on in such a way which ensures splash resistance 4 Set down the bottom section of the TX_44 frame and fasten it with the accompanying Phillips head screws B 3 5 x 16 5 Fit the central inserts and screw them down if n...

Страница 5: ...e for information on how each device is connected Lighting element connection The lighting element of the energy profile is already pre wired up to the connection terminal Proceed as follows to connect the lighting element 1 Remove the connection box from the lower opening of the energy profile and open it 2 Connect the lighting element via the N terminals The available terminals can be used for t...

Страница 6: ... g for path illumination 5 Set the profile cover in place and fasten it with both cover screws Technical data Dimensions W x H x D Profile base 229 x 10 x 155 mm Profile 142 x 491 x 75 mm or 142 x 769 x 75 mm Protection type IP 44 with closed device covers Connections terminal screws 1 x 4 mm2 or 2 x 2 5 mm2 Lamp Light sources with E27 treading of the energy efficiency classes A to E Power 21 W ma...

Страница 7: ...rements via the specialist trade Please submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward the devices to the Gira Service Center ...

Страница 8: ...Co KG Electrical installation systems Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald P O Box 12 20 42461 Radevormwald Germany Phone 49 0 2195 602 0 Fax 49 0 2195 602 191 www gira com info gira com 10866543 49 19 ...

Отзывы: