Operating Instructions

Smoke detector basic

1144 02

Содержание 1144 02

Страница 1: ...Installation and Operating Instructions Smoke detector basic 1144 02...

Страница 2: ...tions 4 Correct behaviour in case of fire 5 Mounting site 6 Unsuitable mounting sites 9 Installation and commissioning 10 Battery check Changing the battery 11 Function test 12 Operating and alarm sig...

Страница 3: ...e German Verband der Sachversicherer VdS Functional principle The smoke detector recognises fire early on due to the smoke development It operates on the scattered light principle Light transmitters a...

Страница 4: ...s accumulators or power supply units as the voltage supply source They can cause malfunctions or a premature failure of the device The smoke detector generates a very loud and shrill sound which can d...

Страница 5: ...ur mouth and nose Do not use any lifts Close the doors and windows of burning rooms in order to prevent the fire and smoke from spreading If it is not possible to flee out of the building find a safe...

Страница 6: ...woken by the smoke alarm during the night Mount the smoke detector in the middle of the room under the ceiling to achieve optimum detection characteristics If this is not possible observe a minimum d...

Страница 7: ...f each floor Optimum protection one smoke detector in each bed and living room or cellar room In buildings with several storeys mount at least one smoke detector in each storey corridor i Recommendati...

Страница 8: ...ular room geometries In L shaped rooms or corridors the smoke detectors should be installed on the centred intersections of the two sections In the case of large L shaped rooms each section is regarde...

Страница 9: ...ts because the air stream may prevent the smoke from approaching the detector Near fluorescent and energy saving lamps because the starter switch may trigger false alarms through the electrical fields...

Страница 10: ...n and insert the battery into the battery compartment 3 Insert the smoke detector into the base and latch it in by turning it slightly clockwise 4 Carry out a function test see Page 12 Legend 1 Dowel...

Страница 11: ...this period Proceed as follows to replace the battery 1 Remove the smoke detector from the base turn counter clockwise 2 Remove the old battery from the compartment and disconnect the connec tor from...

Страница 12: ...ution Hearing damage possible The smoke detector generates a very loud and shrill sound which can damage your hearing Therefore stay at least 50 cm away from it during an function test Signal sound LE...

Страница 13: ...e the dust 2 Wipe the smoke detector with a moist cloth 3 Insert the smoke detector back into the base and turn it clockwise until it latches in 4 Check whether the automatic self test is carried out...

Страница 14: ...failure signal 45 sec cycle 30 days Optical indication LED red Acoustic alarm indication Piezo primary detector Intermittent Volume Approx 85 dB A at 3m Housing dimensions 110 x 40 mm x H Operating t...

Страница 15: ...turn the unit postage paid to our central service department giving a brief description of the fault Gira Giersiepen GmbH Co KG Service Center Dahlienstra e 12 D 42477 Radevormwald Germany The CE sign...