Product characteristics 

The sensor supports the following functions of blind covers: 

Sun protection function enables automatic lowering of the blind/shutter when a set 
brightness value is exceeded.
Application: sun protection for monitor-equipped workstations, flower windows or 
greenhouses. 

Twilight function enables automatic lowering of a blind/shutter when the brightness drops 
below as set value.
Application: lowering the blind/shutter at dusk. 

4 Information for electrically skilled persons 

4.1 Fitting and electrical connection 

Mounting and connecting the device 

The sensor cable carries safety extra-low voltage (SELV). Observe fitting instructions 
according to VDE 0100. 

Figure 2: Sun sensor and included accessories. 

Mount the sun sensor using the mounting bracket (8) in position suitable for brightness 
measurement with the cable entry facing downwards (Figure 2). 

Fasten mounting bracket (8) and housing using supplied screw (6), washer and nut (7).  

Insert sensor cable into the housing from below (5). 

Connect sensor cable to sun (2) and earth (3) terminals (Figure 1). 

Secure sensor cable with strain relief (9). 

Push on transparent housing cover (10) from above until it snaps into place and secure 
from rear with supplied screw (11) (Figure 2). 