APPLICATION NOTE 7100
GRE A
MERICA
, Inc. 425 Harbor Blvd. Belmont, California 94002 phone(650) 591-1400 fax(650) 591-2001
1 of 2
Subject: Connection of GINA 6000N-5 / 8000N-5 to a Model 170 Traffic Controller
The purpose of this note is to provide interface information between GINA 6000N-5 / 8000N-5 and a
Model 170 style Traffic Signal Controller. The information was provided to GRE America, Inc. by
several sources and has been reported as accurate. If an interface problem should still occur after the
steps in this note are taken, please contact the Applications Engineering Office of GRE America, Inc.
1.
The interconnect cable between a Model 170 and GINA is depicted in Diagram No. 1.
Model 170 Controller
GINA
L
2
K
3
N
5
M
8
H
Diagram 1: Cable Configuration
2.
This section demonstrates the programming of a GINA connected to a Model 170 controller
operating at 1200 Kbps. This depicts a Host/Master to Remote operation.
Direct (No Repeater)
Command Abbreviation Value
CHANNEL SELECT
CH=
(User Selects)
COM PORT BAUD RATE
CB=
12,0,1,8
CONMODE
CONM=
2
DEFAULT WAIT
DW=
1
DISPLAY
D=
(Display current settings)
ECHO
E=
0
ENABLE REPEATER
ENR=
0
HARDWARE FLOW
HF=
0
PACKET SIZE
PS=
256
PACKET WAIT
PW=
1,10
REPEATER ID
RID=
0
RESET
RESET
(Resets parameters to default)
RF BAUD RATE
RF=
128
SET TIME AND DATE
STD=
(yymmddhhnnss)
TRANSMIT DELAY
TXD=
5
TRANSMITTER ID
TXID=
0
TRANSMITTER PATH
TXP=
0