Instructions to User

Read these instructions carefully before using this equipment. These 

instructions describe the operating procedures to be followed strictly. 

Failure to follow these instructions can cause measuring abnormality, 

equipment damage and personal injury. The manufacturer is NOT re-

sponsible for the safety, reliability and performance issues and any mon-

itoring abnormality, personal injury and equipment damage due to user’s 

negligence of the operation instructions. The manufacturer’s warranty 

service does not cover such faults. 

-  The contents contained in this manual are subject to change without 

notice.

-  The uncomfortable or painful feeling may appear if using the device 

ceaselessly, especially for the microcirculation barrier patients. It is 

recommended that the sensor should not be applied to the same 

finger for over 2 hours- If any abnormal condition is found, please 

change the position of Pulse Oximeter. 

-  For the individual patients, there should be a more prudent inspecting 

in the placing process. The device can not be clipped on the edema 

and tender tissue.

-  The light (the infrared is invisible) emitted from the device is harmful to 

the eyes, so the user and the maintenance man, can not stare at the 

light.- The Pulse Oximeter is not a treatment device.

-  Testee can not use enamel or other makeup on the finge.

-  Testee’s fingernail can not be too long- Please peruse the relative con-

tent about the clinical restrictions and caution.

1. SAFETY

1.1 Instructions for Safe Operations

-  Check the main unit and all accessories periodically to make sure 

that there is no visible damage that may affectpatient’s safety and 

monitoring performance with regard to sensors and clips. It is recom-

mended that the device should be inspected minimally before each 

use. When there is obvious damage, stop using the oximeter.

-  Necessary maintenance must be performed by qualifid service tech-

nicians ONLY. Users are not permitted to maintain it by themselves.

ENGLISH

Содержание 35091

Страница 1: ...et bien comprendre ce manuel avant d utiliser le produit ACHTUNG Diese Anleitung muss vor dem Einsatz des Produkts aufmerksam gelesen und vollst ndig verstanden werden ATENCI N Los operadores tienen q...

Страница 2: ...d please change the position of Pulse Oximeter For the individual patients there should be a more prudent inspecting in the placing process The device can not be clipped on the edema and tender tissue...

Страница 3: ...OT press the keys on front panel with sharp materials or sharp points High temperature or high pressure steam disinfection to the oximeter is not permitted Refer to User s Manual for instructions of c...

Страница 4: ...re those hemoglobins which release oxygen 2 1 Features Large true color OLED display of SpO2 PR Pulse Bar PI Plethys mogram Innovative 4 directions display Automatic power on off Audible visible over...

Страница 5: ...absorption reflecting and attenuation in tissue can reflect the structure character of the tissue by which the light passes Due to that oxygenated hemoglobin HbO2 and deoxygenated hemoglobin Hb have...

Страница 6: ...e oxygen There is an arterial occlusion proximal to the sensor Blood vessel contraction caused by peripheral vessel hyperkinesias or body temperature decreasing Factors causing low SpO2 Measuring valu...

Страница 7: ...cent lamp dual ruby light infrared heater direct sunlight and etc G Strenuous action of the subject or extreme electrosurgical interfer ence may also affect the accuracy 3 BATTERY INSTALLATION 1 Press...

Страница 8: ...ct position and then clip the finger 3 The device will power on automatically in 2 seconds and start to dis play software version number 4 Next enter into data display screen as shown in Figure 4 The...

Страница 9: ...direction Four directions display alternately Short time press Display Key to flip the screen 90 each time in a cyclical manner as shown in Figure 4 When the screen displays towards the left side the...

Страница 10: ...ual wavelength LED sensor with wavelength Red light 663 nm Infrared light 890 nm Maximal average optical output power 1 5mW Measuring range 35 100 Measuring accuracy 3 for SpO2 range from 70 to 100 Sp...

Страница 11: ...dical Index 2 series while setting the emulating interfer ence of sun light and 50Hz 60Hz fluorescent light J Dimensions 60 mm L 33 mm W 30 mm H Net Weight 35g including battery K Classification The t...

Страница 12: ...E The Pulse Oximeter is calibrated in the factory before sale so there is no need to calibrate it during its life cycle However if it is necessary to verify its precision routinely the user can do the...

Страница 13: ...is not placed far enough inside 2 The finger is shaking or the patient is moving 1 Place the finger correctly inside and try again 2 Let the patient keep calm Cannot turn on the device 1 The batteries...

Страница 14: ...nings carefully Keep away from sunlight Follow instructions for use Keep in a cool dry place SpO2 Oxygen saturation percentage Medical Device complies with Directive 93 42 EEC PR Pulse rate beats per...

Страница 15: ...dity of the warranty GIMA will repair and or replace free of charge all the defected parts due to production reasons Labor costs and personnel traveling expenses and packaging not includ ed All compon...

Страница 16: ...ser of this device should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment RF emissions CISPR 11 Group 1 This device uses RF energy only for its inte...

Страница 17: ...61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical com mercial or hospital envi ronment Table 3 Guidance and manufacturer s dec...

Страница 18: ...termined by an electromagnetic site survey a should be less than the compli ance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol a...

Страница 19: ...paration distance according to frequency of transmitter m 150 kHz to MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 N A 0 12 0 23 0 1 N A 0 38 0 73 1 N A 1 2 2 3 10 N A 3 8 7 3 100 N A 12 23 For transm...