1  -  IntroductIon       

Pipetman

®

  F  fixed  volume 

pipettes are available in 14 
different  models.  Together, 
they  cover  a  range  of  vol-
umes from  to 5000 µL.

The  pipetting  mechanism 
incorporates  a  highly  pol-
ished stainless steel piston, 
a seal, and an O-ring. The 
mechanism  requires  no 
routine lubrication.

Tip-ejector  and  disposable 
tips mean no need to handle 
tips, protecting the user from 
contamination.

The tip-holder, the connect-
ing  nut  and  the  tip-ejector 
are  autoclavable  for  0 
minutes  at  11°C  and  0.1 
MPa pressure.

contEntS 

page

1 -  INTRODUCTION 

2

2 - SPECIFICATIONS 

3

3 -  OPERATION 

4

4 -  USER ADJUSTMENT 

5

5 -  PRE-RINSING 

6

6 -  GILSON DIAMOND

®

 TIPS 

7

7 -  RECOMMENDATIONS 

9

8 -  TROUbLEShOOTING 

10

9 -  SPARE PARTS 

11

EC DECLARATION OF CONFORMITy 

13

Push button Tip-ejector 

button

Body 

or 

handle

Connecting 

nut

Diamond tip

Tip-ejector

Tip-holder

Figure 1

Содержание PIPETMAN F Series

Страница 1: ...PIPETMAN F ENGLISH Other languages available on our website www gilson com...

Страница 2: ...nd disposable tipsmeannoneedtohandle tips protectingtheuserfrom contamination The tip holder the connect ing nut and the tip ejector are autoclavable for 20 minutes at 121 C and 0 1 MPa pressure CONTE...

Страница 3: ...ing genuine Gilson Diamond Tips The data given in the table conform to the ISO 8655 2 Standard Maximum Permissible Errors Model Volume Gilson ISO 8655 Reference L Systematic Random Systematic Random e...

Страница 4: ...rements for each test volume 3 OPERATION Place a tip on the tip holder Press thetiponfirmlyusingaslighttwist ing motion to ensure a positive airtight seal See Chapter 6 for the appropriate tip Always...

Страница 5: ...balances The nominal value of the Pipetman F may be slightly adjusted to compensate for liquids of different density or viscosity Adjustment of the factory calibration must only be performed using a s...

Страница 6: ...ion tool must be turned 3 units until the display reads B 0 2 It is possible to alter the volume by more than one full turn in the counterclockwise direction In this case remember to readjust the same...

Страница 7: ...ty control is maintained throughout the manufacturing process Diamond Tips are used to calibrate Pipetman F therefore for optimum performance you are stronglyadvisedtouseGilson sDiamondTipswith your P...

Страница 8: ...k of precision Theymaybeautoclavedat121 Cfor20minutes at 0 1 MPa Diamond Filter Tips Filter tips are used when sample to sample sample to pipette or sample to operator con tamination must be avoided G...

Страница 9: ...ent this Press and release the push button slowly and smoothly Never turn the pipette upside down Never lay the pipette on its side when there is liquid in the tip Use a dedicated stand or hanger Gils...

Страница 10: ...holder using distilled water Improper reassembly Disassemble the pipette and reassemble the pipette correctly If there is liquid in the tip holder clean the pipette as follows Removethetipejector Unsc...

Страница 11: ...require re calibration of the Pipetman F We recommend thatthisworkiscarriedoutby your Gilson representative Reference Number Item F2 to F20 F25 to F100 F200 F250 to F1000 F5000 Piston assembly F12384...