Assembly:
1. Using a 1/8in Hex Head Wrench, loosen the Allen-Head Set Screws of the Flow Cone Support Ring (A),
located in the sides of each of the three Leg Sockets (B).
2. Insert a Support Leg (C) fully into each Socket and secure by tightening the Set Screws.
3. Set the assembled Flow Cone Stand on a level, sturdy surface and insert the HM-372B or HM-373B Flow
Cone.
4. The assembled set is ready for use following the procedures noted in ASTM C939, Standard Test Meth-
od for Flow of Grout for Preplaced-Aggregate Concrete.
Product Specifications:
•
Dimensions:
•
7.0in (178mm) ID for top 3.0in (76mm)
•
7.5in (190mm) ID Cone Section
•
1.5in (38.1mm) L Discharge Tube
•
Grout Volume 1,725 ±5ml
For technical assistance, contact Gilson at [email protected] or call 800.444.1508.
To order replacement parts, contact Gilson at [email protected] or call 800.444.1508.
HM-372A Support Stand for Grout Flow Cones
A. Flow Cone Support Ring
B. Leg Sockets
C. Support Legs