Please refer to ASTM C939 Standard Test Method for Flow of 

Grout for Preplaced-Aggregate Concrete (Flow Cone Method) 

for exact test procedure.

Grout Flow Cones measure the flowability of hydraulic grout 

used in preplaced aggregate concrete. Flowability is measured by 

time of discharge of a 1.725L sample of grout through an 0.5in 

(12.7mm) ID discharge tube orifice from the cone. The cast alumi-

num Flow Cones all come with an adjustable point gauge assem-

bly to indicate initial sample level. 

Gilson Grout Flow Cones can be purchased in a number of dif-

ferent configurations best suited for your application and needs 

and feature replaceable orifice discharge tubes:

HM-372 Grout Flow Cone Set is supplied complete to meet 

ASTM C939 requirements. An 0.5in (12.7mm) Orifice is already 

installed, and a 3-Legged Steel Support Stand, and 2L (2.1qt) 

stainless steel Beaker for use as a receiving container are also 

included.  

HM-373 Grout Flow Cone Set is identical to the HM-372 set, 

but has a 0.75in (19mm) Orifice to be used with alternate test 

methods.

  Set Components:

•  HM-372A Painted Steel Stand is 20.5in (414mm) high. 

(See assembly instructions below).

•  MA-42 2L Stainless Steel Beaker is rugged construction 

and receives grout flow from cone during test. Graduated 

to 2,000ml, with handle. Larger MA-48 6qt. container is 

available separately for continuous testing

HM-372B Grout Flow Cone is fitted with HMA-146 0.5in Orifice 

to meet ASTM requirements. Stand and Beakers can be pur-

chased separately.

HM-373B Grout Flow Cone is fitted with HMA-147 0.75in Ori-

fice for use with alternate test methods. Stand and Beakers can 

be purchased separately.

HM-371 Grout Flow Cone w/No Orifice does not include an 

Orifice to regulate flow. It can be fitted with the HMA-146 0.5in 

Orifice for ASTM testing, or the HMA-147 0.75in Orifice for other 

methods. Orifices are purchased separately. Before use, install 

the selected Orifice fixture using the four screws provided.

  Cleaning and Maintenance

•  Immediately after each use, thoroughly clean the cone, ori-

fice and point gauge assembly with water and a medium-

stiff bristle brush. Allowing mortar and cement paste to dry 

and accumulate on the cone, orifices and gauge may affect 

accuracy.

•  Do not use metal scrapers or wire brushes when cleaning 

as these may damage the surfaces. 

•  Using a thin film of light grease on the threads of the point 

gauge will make it easier to operate and reduce cleaning 

effort.  