background image

10

keY conTRols 

|

 

FC 203B FraCtion ColleCtor

Key C

O

ntr

O

ls

more

Press this key to see the next display of a HelP message. 

Refer to 

Back

 on page 9.

ok

Press to apply the instructions shown on the top line of 

the display. Works in the same way as the 

YeS Hard Key

.

Peak

specifies collection in one of the two peak modes. 

After making this selection, select to subfractionate 

peaks by time or by drop. Refer to 

Collection Modes

 on 

page 2 for more information.

Quit

Press to return to the previous display.

Rack

Press to tell the fraction collector which rack will be 

used. change the rack code by entering a new number. 

Also calls up a description of the rack code that 

currently appears on the display. Refer to 

racks

 on 

page 16 for more information.

start

Press to start the collection. The 

Start Hard Key

 has the 

same function.

Time

specifies collection in time mode. Refer to 

Collection Modes

 on page 2 for more information.

Содержание FC 203B

Страница 1: ...Gilson Inc 3000 Parmenter Street PO Box 620027 Middleton WI 53562 USA Tel 608 836 1551 or 800 445 7661 F 608 831 4451 www gilson com FC 203B Fraction Collector Quick Reference Guide...

Страница 2: ...2016 Gilson Inc All rights reserved LT1732 05...

Страница 3: ...w 1 Customer Service 2 Notable Features 2 Collection Modes 2 Racks 2 Operation 3 Memory 3 HELP 3 Cycle Collection 3 Collection Windows 4 Key Controls 5 Hard Keys 5 Cycle Collection 11 Collection Modes...

Страница 4: ......

Страница 5: ...necessary plumbing and electrical connections Use the quick reference guide for information about control keys operating modes programming available racks input output control For more detailed infor...

Страница 6: ...local Gilson representative Specific contact information can be found at www gilson com Notable Features Collection Modes Choose from several collection modes time drop peak plus time peak plus drop o...

Страница 7: ...ols on page 5 for more information Memory The fraction collector remembers its last set of instructions e g the operating mode and the numerical values assigned to the various options even if the powe...

Страница 8: ...es aiding in selective peak collection Remember four key points about collection windows It is always possible to collect from start to end designating the entire collection period as one collection w...

Страница 9: ...of the unit Typically the dispense head will return to home after collecting into the last tube in the rack When using the multiple column option press END after the last fraction has been collected...

Страница 10: ...r rather than tube number is displayed Typically tube advance is automatic but it is possible to manually initiate an advance by pressing ADV or advance remotely as described in the user s guide To un...

Страница 11: ...el the next one or the first vessel in the next row 0 9 Press number keys to enter numerical values The decimal point where applicable does not have to be entered One easy way to enter a new number is...

Страница 12: ...l effluent will be discarded Collection windows are optional Add up to ten windows Refer to the user s guide for detailed instructions Collect Press to collect the non peak effluent in peak modes Coll...

Страница 13: ...account for the time it takes effluent to pass from the detector to the fraction collector Discard In peak modes press to divert the non peak effluent to the drain Drop Specifies collection in drop mo...

Страница 14: ...ractionate peaks by time or by drop Refer to Collection Modes on page 2 for more information Quit Press to return to the previous display Rack Press to tell the fraction collector which rack will be u...

Страница 15: ...per cycle Parameter in the Technical Menu press EDIT 2 allows for indicating how the fractions will be collected To collect each sample into the same set of tubes set the Tubes per cycle Parameter to...

Страница 16: ...s _ _ _ _ min tube Collect _ _ _ _ to _ _ _ _ collection windows Optionally change min tube values during the run Enter new numbers and then press YES Drop Mode For collection of fractions by drop cou...

Страница 17: ...ameters Delay time _ _ _ min Collect _ _ _ _ to _ _ _ _ collection windows Peak Modes Choose to collect peak and or non peak fractions To detect peaks the fraction collector must be connected to an an...

Страница 18: ...collected the time it takes for the effluent to pass from the detector flow cell to the dispense head of the fraction collector This aids in the collection of purer peaks The user s guide explains how...

Страница 19: ...s will not appear if discard non peak fractions was selected Peak width _ _ _ min Peak height _ _ _ mV or Peak level _ _ _ mV Delay time _ _ _ min Collect _ _ _ _ to _ _ _ _ collection windows It is p...

Страница 20: ...et the rack code to 0 Code 0 rack For 80 12 mm diameter vials Code 1 rack For 80 13 mm diameter tubes Code 2 rack For 119 6 mm diameter tubes Code 4 rack For 80 12 mm diameter tubes Code 11 rack For 1...

Страница 21: ...s guide for diagram Code 29 SE rack For 60 8 mm Eppendorf vials Set rack code to 29 if using vials without caps If using capped vials place vials in center two rows with caps facing outward set rack...

Страница 22: ...d in peak modes Pin 1 is signal 10 100 mV Pin 2 is ground reference 3 4 Input A When activated by contact closure fraction collector will start a run or if already in run will advance to the next tube...

Страница 23: ......