INTRODUCTION

 

CENTRY™ 103 MINICENTRIFUGE

Description

3

1

2

8

10

4

5

6

7

9

12

14

13

11

15

1

Lid

2

Chamber

3

Motor shaft boss

4

Power indicator light

5

Main power switch

6

AC adapter connector 

7

Battery compartment 

4 AA size / LR6, alkaline 

batteries (1.5V)

8

Rotor for microtubes: 

8 microtubes of 1.5 mL or 2.0 mL

9

Rotor for tube–strips:

2 lines of 8 connected 0.2 mL microtubes

10

AC adapter 

Input voltage: AC 100–240V, 50/60 Hz

11

Type C (EU)

12

Type A (Japan/USA)

13

Type A (China)

14

Type G (UK)

15

Type I (Australia)

Figure 1

CENTRY

TM

 103 Minicentrifuge components

Содержание CENTRY 103 Minicentrifuge

Страница 1: ...User s Guide EN CENTRY 103 Minicentrifuge...

Страница 2: ...and Microtubes 5 Batteries 5 OPERATION 6 Installing 6 Connecting to the Power Source and Turning On 6 Installing the Rotor 7 Preparing the Microtubes 8 Starting and Ending Operation 8 Using Batteries...

Страница 3: ...in the lid The CENTRY 103 Minicentrifuge will automatically decelerate to a stop after six minutes of continuous spinning Ordering Information DESCRIPTION PART NUMBER CENTRY 103 Minicentrifuge F11073...

Страница 4: ...AC adapter connector 7 Battery compartment 4 AA size LR6 alkaline batteries 1 5V 8 Rotor for microtubes 8 microtubes of 1 5 mL or 2 0 mL 9 Rotor for tube strips 2 lines of 8 connected 0 2 mL microtub...

Страница 5: ...ntal fire short circuit or malfunction Never open the lid while the rotor is spinning accidental contact with the spinning rotor may cause serious injury When leaving the instrument out of use for a l...

Страница 6: ...unlight Avoid installing the minicentrifuge on a slippery surface or surface prone to vibration WARNING Do not install the instrument in facilities that store chemicals that could generate flammable g...

Страница 7: ...locked inside the hole of the rotor For dismounting the rotor hold it by both hands and push the tabs inward with two thumbs to disconnect them from the rotor and then pull the rotor out from the moto...

Страница 8: ...ng run Starting and Ending Operation By closing the lid 1 the rotor instantly starts spinning After six minutes of spinning the rotor will automatically decelerate to a stop WARNING Ensure that there...

Страница 9: ...oclave or with UV it could damage them The rotors can be disinfected with ethanol Inspecting and Maintaining Check the rotor main body and lid for damage deformation and corrosion Check the lid to mak...

Страница 10: ...t is activated Turn off the power switch and wait at least one minute The rotor stops while it is spinning Motor s overcurrent is detected by unbalanced load and the overcurrent protection circuit is...

Страница 11: ...R S GUIDE Chapter 5 SPARE PARTS Accessories DESCRIPTION PART NUMBER CENTRY 103 ROTOR 8 TUBES 1 5 2 0 mL F1077310 CENTRY 103 ROTOR 2 TUBE STRIPS 8 X 0 2 mL F1077311 CENTRY 103 MOTOR SHAFT BOSS F1077312...

Страница 12: ...voltage equipment 2014 35 EU Electromagnetic compatibility 2014 30 EU Restriction of hazardous substances 2011 65 EU Standards for EU Safety requirements for electrical equipment for measurement cont...

Страница 13: ...only if the instrument is used in the manner described in this guide and for the purpose for which it is designed Gilson is not responsible for consequential damages resulting from the misuse or bad c...

Страница 14: ...www gilson com contactus LT801606 A 03 2019 Gilson Inc All rights reserved...

Отзывы: