Your new sensor has been factory set up to operate straight from the box using factory default
parameters suited to a wide variety of applications. This allows the minimum of set up activities for most
applications. See factory default settings for more information.
Getting Started
Models with display:
• Remove the display electronics cover as shown in Fig 1. Using a Phillips screwdrive
• Thread multi-core wire through the enclosure grommet as shown in Fig 2 and add the bootlace
ferrules ready for connection within the display enclosure.
• Connect the wires to the terminal blocks within the sensor according to tables I, II, III.
• Replace the display electronics cover and gasket as shown in Fig 1 to a tightness of 4Nm +/-
0.4NM during re-assembly.
All Models:
• Using tables I & II, connect the sensor according the sensor output type being installed (4-20mA
and 0-10V – table I, CAN – table II)
Note: Please observe the minimum and maximum operating values for the sensor as shown in the table above.
Note: For voltage devices, the analogue output is limited by the supply voltage provided to power the sensor
and a minimum 0.7V power supply headroom above the desired analogue output is recommended for stable
sensor output.
Fig 1
Fig 2
Voltage Output
Current Output
CAN
Supply Voltage
+6 to +28 VDC
+9 to +28 VDC
+5 to +28 VDC
Power Suppy
Rating (min)
3W
4W
3W
Table I
Table II
Table III