background image

4223 

Lightweight Liquid Level Sensor 

Gill Sensors 

Controls Limited 

Unit 600 Ampress Park 

Lymington, Hampshire SO4 l  SLW 

United Kingdom 

Tel: +44 (0) 1590 613 900 

Fax +44 (0) 1590 613 901 

[email protected] 

User Manual 

www.gillsc.com 

4223-30-090 lss. 2 

Copyright© Gill Sensors & Controls Limited 201

8

 

Содержание 4223

Страница 1: ...l Sensors Controls Limited Unit 600 Ampress Park Lymington Hampshire SO4l SLW United Kingdom Tel 44 0 1590 613 900 Fax 44 0 1590 613 901 info gillsc com User Manual www gillsc com 4223 30 090 lss 2 Copyright Gill Sensors Controls Limited 2018 ...

Страница 2: ......

Страница 3: ...ctronics are housed in the flange outside the liquid container The outer tube and inner rod are placed into the liquid container such that they will be submerged in liquid when the container is not empty Calibration of the sensor is achieved by setting a maximum full and minimum empty level for the desired liquid The liquid level between these points is determined using software while taking accou...

Страница 4: ...y measurement considerations Top exit PROBE LENGTI 1 7 0 TOTAL MEASUREME NT RANGE A t 8 0 N O N L IN EA R M E AS R U E M E N T RA N G E Side exit PROBE LENGTH XXX PROBE LENGTH 7 0 TOTAL MEASUREMENT RANGE A 1 8 0 N O N L IN EA R M E AS U R E M E N T RA N G E PROBE LEN GTH XXX 4223 30 090 lss 1 3 0 ADAPTER MOUNTING DEPTH MIN BEND 40 0 3 0 ADAPTOR MOUNTING DEPTH 4 ...

Страница 5: ...utput range of 0 25 V to 10 V The power supply must be at least 0 5V greater than the maximum output voltage required The switch output requires a pull up resistor of 1 kOhm to 1O kOhms 2 2 SECONDARY OUTPUT The sensor s secondary output is determined by the customer on order and cannot be altered Switch Temperature 4223 30 090 lss 1 Open collector output of 50V 1Amax switch to V ground Configurabl...

Страница 6: ... sensor with a computer Gill Sensors Controls Limited provide an RS232 to USB adaptor P N 1484 00 086 The sensor can be powered through the adaptor using the V and V leads and communicated with using the Tx and Rx leads Please contact us if you require this device The GSlevel User Manual is accessible through the software Install and run the software then click the Help button in the bottom right ...

Страница 7: ...upplied so that it reports the level in a linear path as the level rises However this will not be suitable for an irregular shaped tank such as that shown below Sensor Full Level 100 Half Level 50 Liquid lrregularTank Empty Level 0 In this situation 50 of tank volume is not half way up the probe To correct for this tank profiling can be used This can be done in the GSlevel software and is covered ...

Страница 8: ...of sensors in the conventional manner see below For inverted installation see below please contact Gill Sensors Controls Limited Conventional factory calibration MIN ___ 7Liquid Inverted The 4223 sensor can be mounted using a variety of 1 hole 2 hole 3 hole 5 hole and threaded adaptors An 0 ring seal is used for 1 hole and may be used for 2 3 5 hole adaptors while a panel gasket is used for 2 3 5 ...

Страница 9: ...nsor O ring seal s and or panel gasket 2 3 5 hole as required Adaptor M3x6 CSK screws qty 3 Quick Start Guide 4 2 CABLE LENGTH STRAIN RELIEF The sensor is provided with a flying lead of 1000mm which may be shortened appropriate to the application Ensure that the cable is secured to avoid damage during operation It is recommended that cable length is kept to a minimum to prevent large voltage drops...

Страница 10: ...e fitted with the 19 x 1 5 mm fluorosilicone O ring seal as shown in the diagram below Fitting the sensor adaptor The sensor must then be fitted with the adaptor 1 2 3 5 hole or threaded adaptor using the three supplied M3 x 6 mm CSK screws as shown in the diagram below The adaptor has 3 possible orientations for 1 2 3 hole and threaded adaptors for the correct orientation of the 5 hole adaptor se...

Страница 11: ... adaptor fitting holes align with their holes in the sensor and the cable is in the position shown Fitting the fluorosilicone panel gasket or fluorosilicone 13 x 1 5 mm O ring seal You can use the fluorosilicone panel gasket with the 2 3 or 5 hole adaptors Fit the panel gasket as shown in the diagram below such that holes in the panel gasket line up with the mounting holes of the adaptor Note if y...

Страница 12: ...sing the 13 x 1 5 mm O ring you do not need the panel gasket 0 The sensor is now ready for installation into the tank 4 4 RECOMMENDED MOUNTING APERTURE FOR ADAPTORS For O ring seal with 1 2 3 and 5 hole mounting adaptors The recommended mounting aperture and chamfer size for use with the O ring seal and 1 2 3 and 5 hole adaptors is shown below Ensure that sufficient space is available around the s...

Страница 13: ...able around the sensor flange for the cable to bend Note all panel gaskets are 2 mm thick BREAK SHARP SENSOR MOUNTED THIS SIDE z N I EDGE 0 2 MAX 1 PZZ1 l j __ 1 016 20 1 For M22 x 1 5 mm threaded flange mounting adaptor The recommended mounting aperture for use with the M22 x 1 5 mm threaded mounting adaptor is shown below Ensure that sufficient space is available around the sensor flange for the...

Страница 14: ...re that the tapped holes do not penetrate entirely through the tank wall as this will prevent a proper seal from being maintained A diagram of each mounting adaptors is provided below to enable the holes to be tapped in the correctposition In the case of the threaded flange mountingadaptor a cross sectional view has also been provided for greater detail 1 hole mounting adaptor 0 CV N 4223 30 090 l...

Страница 15: ...4223 Lightweight Liquid Level Sensor 2 hole mounting adaptor 0 0 0 l 3 hole mounting adaptor 4223 30 090 lss 1 Gill Sensors Controls Limited R6 0 3 POS 15 ...

Страница 16: ...4223 Lightweight Liquid Level Sensor 5 hole mounting adaptor M22 x 1 5 mm threaded flange mounting adaptor 36 0 NF I M22x1 5 l 4223 30 090 lss 1 Gill Sensors Controls Limited 0 0 O I 16 ...

Страница 17: ...g 6ms 1000 shocks positive and negative in each of 3 axes Resonant frequency search 5 to 2500Hz 0 Sg peak 10 bar absolute and differential 1m in packaging on all 3 sides to BS EN 60068 2 14 test Na Dry heat to BS EN 60068 2 2 test Bb Cold to BS EN 60068 2 1 test Ab Damp heat to BS EN 60068 2 30 test Db EMC immunity BS EN 60945 BS EN 61326 and BS EN 61000 6 1 2 3 4 Probe length Mounting options Sea...

Страница 18: ...tion engraved on the flange lid The interpretation of the part number designation is outlined below Length Range mm Cable exit 1 100 250 S sideexit 2 251 500 T top exit 3 251 750 Secondary Output Y temperature N switch I I I I 4223 00 XXX XXX X 4223 30 090 lss 1 I Product Number Length mm Mounting Adaptors 0 noadap tor A l hole B 2hole C 3hole D 5hole E M22 x 1 5 thread I 18 ...

Страница 19: ...ontrols Limited Contact details can be found on the front of this document 6 2 RETURNS If Gill Sensors Controls Limited require the sensor to be returned you will be issued with an RMA number Please DO NOT return the sensor without having first obtained an RMA number This will enable your sensor to be tracked and updates provided 6 3 DECOMMISSIONING To dispose of the sensor follow local waste disp...

Страница 20: ...4223 Lightweight Liquid Level Sensor Gill Sensors Controls Limited 7 APPENDIX CE DECLARATION 20 ...

Страница 21: ......

Страница 22: ...trols Limited Unit 600 Ampress Park Lymington Hampshire SO41 SLW United Kingdom Tel 44 0 1590 613 900 Fax 44 0 1590 613 901 info gillsc com www gillsc com 4223 30 090 lss 2 Copyright Gill Sensors Controls Limited 2018 ...