MDE-4318D Competitive Pump and CRIND (CPC) Hardware/Software Start-up and Service Manual · May 2010
Page 29
Installing the PA0338X00X D-Box
PA0338X00X D-Box Installation
The table below provides a quick reference to field wiring and proper connections for a CPC
installation.
Configuring the D-Box Jumper Settings
The T19547-G1 D-Box Board must be jumpered for a 34 mA loop for proper communication
to Wayne dispensers. See
“Description of Jumper Settings”
for details
regarding jumper settings for the CPC D-Box.
Figure 2-9: D-Box to CATs and Dispensers
Description of Jumper Settings
Description
T19547-G1 Board
Jumper Settings
T20488-G2 Board Jumper Settings
2 boards, 2 input, 8 loops, 34 mA for
Wayne UL-listed dispensers
JP10 “In”
JP11B “In”
JP13B “In”
• JP1-JP8 “In” on positions connected to
CATS
• JP1-JP8 “Out” on positions not
connected to CATS